Setup regulations
Operation outdoors
The device can be installed and operated outdoors in accordance with its degree of pro-
tection IP 23. However, the installed electrical parts must be protected from direct expos-
ure to moisture, e.g. external wet cleaning.
Ambient temperature
IMPORTANT!
The operating and storage temperature must not fall below the following
temperatures:
-
without cleaning electrolyte: -25 °C / -13 °F
-
with cleaning electrolyte: 0 °C / 32 °F
Install the device in such a way that it is not additionally heated by heat sources such as
radiators, heaters or annealing furnaces, direct sunlight, etc.
Warning notices
on the device
The device is equipped with warning notices and a rating plate.
The warning notices and rating plate must not be removed or painted over.
Model No.
Part No.
Ser. No.
FRONIUS INTERNATIONAL GMBH
Froniusplatz 1, A-4600 Wels, Austria
Phone: +43 (0)7242 241-0
MAGIC CLEANER MC 150
.........................
.........................
CAN/CSA-E60974-1: 2012
ANSI/IEC 60974-1:2008
1~
50/60Hz
IP23
U0 = 30V AC Rms - 30V DC peak
U1 = 85-260V
U2 = 0 to 30V AC/DC
P1max = 450W
L1 max = 5A
L2 = 0 to 15A
Duty (%) = 0 to 80%
Rating plate and warnings on the device
Use eye protection / safety goggles
Use respiratory protection
Use gloves
Use protective equipment according to the safety data sheet of the cleaning
electrolyte used!
Caution! Corrosive liquids