![Fronius Eco 15.0-3-208 US Installation Instructions Manual Download Page 37](http://html1.mh-extra.com/html/fronius/eco-15-0-3-208-us/eco-15-0-3-208-us_installation-instructions-manual_2339156037.webp)
37
EN-US
Foreword and safety instructions
Safety
Protective Mea-
sures against
ESD
Safety Inspection
This chapter describes the safety inspection for the device described in this service man-
ual.
Please observe the requirements and standards for your particular country, since there
may be deviations in the measured values or inspection steps.
If there are no requirements and standards for your particular country, Fronius recom-
mends that this inspection is still carried out.
The safety inspection must only be conducted on a completely assembled device.
Tools required
-
Torx screwdriver, TX25
-
Diagonal cutting pliers
-
Needle-nosed pliers
-
Torque screwdriver with bit insert, 1–6 Nm
WARNING!
Work performed incorrectly can cause serious injury and damage. All
activities described in the service manual must only be carried out by a trained
Fronius service technician. Please note the information in the "Safety Rules"
chapter in your inverter operating instructions.
WARNING!
An electric shock can be fatal. Before opening the device
-
Set power switch to - O -
-
Disconnect the device from the grid
-
Attach a clear warning sign advising others not to switch the power source
back on
-
Use a suitable measuring tool to ensure that electrically charged components
(e.g. capacitors) are discharged.
WARNING!
An electric shock can be fatal. If the device is briefly switched on with
an open housing for test purposes,
-
do not touch the components inside the housing
-
touch them only with suitable measuring or test probes
WARNING!
An inadequate grounding conductor connection can cause serious
injuries to persons and damage to (or loss of) property. The housing screws pro-
vide an adequate grounding conductor connection for the housing ground and
should not under any circumstances be replaced by other screws that do not pro-
vide a proper grounding conductor connection.
Danger of damage to electrical components from electrical discharge. Suitable
measures should be taken to protect against ESD when replacing and install-
ing components.
Summary of Contents for Eco 15.0-3-208 US
Page 2: ...2...
Page 4: ...4...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 8: ...8 Mess und Pr f mittel Digitales Multimeter Equipment f r die sicherheitstechnische berpr fung...
Page 9: ...Einbau State 112 KIT...
Page 10: ......
Page 15: ...15 DE 1 2 3 4 5 1 2 3 4 22 1 lbf in 2 5 Nm 5...
Page 19: ...Sicherheitstechnische berpr fung...
Page 20: ......
Page 32: ...32...
Page 34: ...34...
Page 35: ...General Information...
Page 36: ......
Page 38: ...38 Measuring and In spection Equip ment Digital multimeter Equipment for safety inspection...
Page 39: ...Installation State 112 KIT...
Page 40: ......
Page 45: ...45 EN US 1 2 3 4 5 1 2 3 4 22 1 lbf in 2 5 Nm 5...
Page 49: ...Safety inspection...
Page 50: ......
Page 62: ...62...
Page 63: ...63 EN US...