E18
Cause:
Wrong firmware (software) has been loaded
Remedy:
Contact after-sales service
E19 / E22
Cause:
Battery fault
Remedy:
Contact after-sales service
E23
Cause:
A voltage of > 113 V DC has been measured on the current sockets
Remedy:
Contact After-Sales Service
No function
The power source cannot be switched on
Cause:
The battery has entered a state of deep discharge as it has been stored for
too long without being charged
Remedy:
Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Cause:
Control panel defective
Remedy:
Contact After-Sales Service
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no charging
indicator on the power source
Cause:
Device is too hot
Remedy:
Check/reduce ambient temperature, allow battery to cool down
Cause:
Device temperature too low
Remedy:
Check/increase ambient temperature
No welding current
Power source is switched on, indicator for the selected welding process is lit
Cause:
Welding power-lead connections have been disconnected
Remedy:
Establish proper welding power-lead connections
Cause:
Poor or no earth
Remedy:
Establish a connection to the workpiece
Cause:
There is a break in the power cable in the welding torch or electrode holder
Remedy:
Replace welding torch or electrode holder