47
EN
VRD safety device (optional)
General
VRD is an additional safety device that prevents, as far as possible, output voltages that
may pose a danger to persons.
VRD = Voltage Reduction Device.
Function
VRD is active
The welding circuit resistance is greater
than the minimum human body resistance
(greater than or equal to 200 Ohm):
-
VRD is active
-
Open circuit voltage is limited to 14 V
-
The VRD indicator lights up
-
Example:
no risk ensues if both wel
-
ding sockets are touched accidentally
at the same time.
VRD is not active
The welding circuit resistance is less than
the minimum human body resistance (less
than 200 Ohm):
-
VRD is inactive
-
Output voltage not limited in order to
ensure sufficient welding power
-
The VRD indicator does not light up
-
Example:
Start of welding
NOTE!
Within 0.
3 seconds of the end of welding:
► VRD is active again
► The output voltage is limited to 14 V again