ERRORS DURING OPERATION
THE CARRIAGE DOES NOT STOP AT THE LOWER OR UPPER LIMIT STOP MICROSWITCH
Problem suggestion
Possible solution
- Proximity/Micro switches are not
connected properly
- Check the wiring
If the carriage is in the LOWEST Magnet sensor
2 (
Fig. 2
)
LED L24 (3) is ON (
Fig. 3
)
- If the carriage is in the HIGHEST
Magnet sensor 1 (
Fig. 1
)
LED L25 (3) is ON (
Fig. 3
)
- If the carriage is in ZERO position
LED L24 & L25 are OFF (IF PA06=10)
Means carriage in not at lower or upper
proximity.
- Proximity/Micro switch malfunctioning
- Control the distance proximity (1) (
Fig.1
) bracket
mounted on the carriage. Max 4-6mm distance.
- Control the micro (2) (
Fig.2
) The lever should be
able to move up and down
- Replace the proximity sensor.
- Replace the micro sensor.
- Carriage
doesn’t wrap at turntable level
- Check for the position of the lower cam by
adjusting the respective adjuster screws.
Fig.1
Fig. 2
Fig. 3
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
3
2
1