Test data pellets - Emissions in [mg/MJ] (RL / PL)
Carbon monoxide (CO)
mg/MJ
5 / 16
5 / 11
4 / 6
Nitrogen oxide (NOx)
mg/MJ
64 / 57
67 / 57
70 / 58
Organic hydrocarbons (OGC)
mg/MJ
<1 / <1
<2 / <2
<2 / <2
Dust
mg/MJ
24 / 14
18 / 12
11 / 9
Boiler efficiency
%
90,8 / 93,4
92,1 / 92,7
93,5 / 92,0
Test data pellets - Emissions in [mg/m³]
1)
(RL / PL)
Carbon monoxide (CO)
mg/m³
8 / 23
7 / 16
6 / 8
Nitrogen oxide (NOx)
mg/m³
94 / 84
98 / 85
103 / 86
Organic hydrocarbons (OGC)
mg/m³
<1 / <1
<2 / <2
<2 / <2
Dust
mg/m³
35 / 21
25 / 17
15 / 13
Boiler efficiency
%
90,8 / 93,4
92,1 / 92,7
93,5 / 92,0
1.Emissions values are based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%