❒ Remove the securing pin (7) and pull out the WOS shaft (5).
❒ Remove the washer (8).
❒ Unscrew the bearing bush (9) on the shaft.
❒ Remove the blanking plug (10) from the opposite side.
❒ Insert the WOS shaft (5) with the washer (8) on the opposite side and push it
through.
❒ Refit the bearing bush (9) and blanking plug (10) that you removed previously on
the opposite side.
❒ Secure the shaft (5) with the securing pin (7).