Assembling the Pellet Boiler
3.3.1
Removing the suction cyclone
U
Remove sound insulation cover
U
Open the clamps on the suction unit container and lift the cover
´
The induced draught unit set is in the suction unit container
3.3.2
Fitting the induced draught fan
U
Remove pre-installed cover plate
U
Unscrew pre-installed nuts and
spacer washers
U
Attach and fix the ID fan as
illustrated
The straight edge must be up.
U
Join both cables of the ID fan with the pre-installed cables
U
Push the cable behind the cladding and put back the cover plate.