![Fröling Lambdatronic S 3100 Instructions Manual Download Page 26](http://html1.mh-extra.com/html/froling-0/lambdatronic-s-3100/lambdatronic-s-3100_instructions-manual_2338760026.webp)
Control Sy
stem
Lamb
datro
nic S 3100
SERVICE INSTRUCTIONS
FRÖLING Heizk
essel und Be
hälterbau
GmbH
B 018 10 04
A-4710 Grieskirchen, Industriestr
aße 12,
Tel.: +43 (0)724
8/606-0
Page 11 of
24
5.7 MANUAL DIGI
IN
Used to test the digital in
puts and is
inten
ded onl
y for heatin
g engin
eers.
The displa
y de
pends on
the config
uration.
Door sensor
A 0
←
Limit ther
mostat
emer
gency stop
A 1
←
Safety temp
erature limiter
EMERGE
NCY S
TO
P
A 0...
Automatic,
OFF
A...
AUTO
MATIC
A 1...
Automatic,
ON
0...
Manual
OFF
1...
Manual
ON
5.8 SYSTEM
SE
LECTION
Parameter “
FHG ...
” must be set for the F
HG
Tu
rbo 3000.
Boiler type...
←
FHG Eco 1
5 …
X
←
FHG Turbo
20 …
Lambda prob
e in
flue gas pi
pe
N
←
Y, if a Lamb
da probe is available.
FHG Turbo
30 …
FHG Turbo
40 …
Comb
. cham
b.
sensor av.
N
←
Y, if a combustio
n chamber
sensor is available.
FHG Turbo
50 …
FHG Turbo
70 …
Actu
ato
r w
ith
feedback
N
←
“Y”...Actuators
with feedback have
six terminals.
“N”..Actuators
without feedback ha
ve three terminals
P2 – 15 kW ...
P2 – 25 kW ...
P3 – 9.9 kW ...
P2/P3 ... do not select, set arrow
to
FHG.
There are 13 system gro
ups avail
abl
e:
Syst
em 0 to 9
,
12 to 15
. By select
ing the param
eters, there are severa
l
options ava
ilab
le
withi
n the s
ystem groups.
You w
ill find a
n overvie
w in ch
apter 5.8.1 Sys
tems
.
Use the “arrow up” and “arr
ow
dow
n” b
uttons
to select the relevant s
ystem
.
System...
←
System 0...
←
System 1...
X
←
Press “
Enter
” to
confirm the s
ystem selection – the display
w
ill show a
submenu in w
hich furthe
r settings are to be made (
see also
chapter 5.8.2
System param
eters)
The selected system is marked
with a
X
.
System 2...
←
....