![Fröling Lambdatronic S 3100 Instructions Manual Download Page 24](http://html1.mh-extra.com/html/froling-0/lambdatronic-s-3100/lambdatronic-s-3100_instructions-manual_2338760024.webp)
Control Sy
stem
Lamb
datro
nic S 3100
SERVICE INSTRUCTIONS
FRÖLING Heizk
essel und Be
hälterbau
GmbH
B 018 10 04
A-4710 Grieskirchen, Industriestr
aße 12,
Tel.: +43 (0)724
8/606-0
Page 13 of
24
6 Initial
start-
up
Follo
w th
e individu
al steps in this chapter
when starting u
p for the first time.
Note:
Follo
w the con
nection i
nstructions i
n c
hapter 9 before
sw
itchin
g on the system
!
6.2
Switching
on the system
The main s
witc
h is on the l
eft han
d side of the control cas
ing
.
Fröling:
. . . .
. . .
. .
After sw
itching
on the control
unit, the w
ord
FR
ÖLING appears.
The control uni
t performs a system check.
Off
boiler temp.
37°
After the syste
m check, the di
splay me
nu w
ill appe
ar.
Th
is w
ill sho
w the ACT
UAL values.
6.3
Changing the user code
Off
boiler temp.
37°
The user code
must be chang
ed in the disp
lay men
u.
User name
CUSTOMER
←
Hold dow
n t
he “
arr
ow d
own
” button u
ntil
you reach the e
nd of the displ
ay
menu. You w
ill
be
able to see the
current user level her
e.
User Code:
0
←
Press the “
Enter
” button. A questio
n mark
will ap
pear. No
w enter the cod
e for the “
Installer
”
or “
Service
” user leve
l. Confirm b
y press
ing
“
Enter
”. If you enter the
wro
ng code, the co
de
for “child lock” w
ill a
utomatically
be
used
.
Code
1
...
custo
mer,
code
0
...
child lock,
display for child lock “
-------
”.
User code: Install.
The name of the set user leve
l (Install.
or Service) w
ill ap
pear briefl
y.
Off
Boiler temp.
37°
The displa
y w
ill then go b
ack to the top of the
displa
y m
enu.
In the “child loc
k" code
you
will
only b
e ab
le to see the d
ispl
ay me
nu and t
he ERROR DISPLAY. It is not possibl
e to
change the p
ara
meters.
6.4
System sel
ection: boiler type, s
ys
tem
Off
Boiler temp.
37°
Sw
itch
to the user menu b
y pr
essing the “
Enter
" button onc
e.
SET
←
ERROR DISPLA
Y
Hold dow
n t
he “
arr
ow d
own
" button u
ntil
you reach the “s
yste
m selection"
parameter at the
end of the setting men
u.
SYSTEM
SELECTION
←
Press the “
Enter
" button to sw
itch
to the “Parameter grou
p".
Boiler type...
←
System...
Use the “arrow up" an
d “arrow
dow
n"
button to
positi
on the arro
w at the des
ired parameter
group. No
w s
witch to the sub
menu b
y pr
essing “
Enter
“.
For a description of the par
am
eters, pleas
e see chapt
er 5.8 SYSTEM SE
LECTION.