❒ Fit adjustable feet (F) to flange plate on boiler room side
➥ Adjust height as required
❒ Fit gear supports (G1) to mitre gear
➥ Adjust height as required
➥ Use shortened gear supports (G2) for horizontal installation (optional)
➥ Where required use extension (G3) for gear supports (optional)
❒ Place geared motor (I) with torque support and spacer tube (H) on shaft stub
➥ Thread torque support into counter bearing
➥ Ensure groove in shaft stub is aligned with groove in geared motor
❒ Slide key into groove and fit shaft retainer
❒ Align rotary agitator in store as per installation diagram
➥ The rotary agitator duct should be fitted in the centre of the store at an angle of
90° to the wall
❒ Secure gear supports and adjustable feet to floor
⇨ See "Securing the adjustable feet and support elements" [page 32]
Installation
4
Installing the discharge system
Installation and Operating Instructions | M1730116_en