![Froilabo BM340 User Manual Download Page 49](http://html1.mh-extra.com/html/froilabo/bm340/bm340_user-manual_2338685049.webp)
45
-
Risk of asphyxiation and loss of consciousness.
An atmosphere with less than 16% oxygen is hazardous
(nitrogen gas displaces oxygen in the air).
-
Nitrogen gas builds up in low areas.
-
Risk of frostbite.
-
Risk of corrosion of steels in the presence of humidity.
-
In closed vessels, the pressure can reach very high values (in the order of 700 bar) resulting in a risk of bursting.
Critical precautions to be taken:
-
Areas where liquid nitrogen is stored or used must be well ventilated (extraction or ventilation at both high and
low levels in the room).
-
Areas liable to contain an unbreathable atmosphere must be indicated with an
asphyxiation hazard
pictogram.
-
Never enter a room that has contained liquid nitrogen without taking predefined precautionary measures.
-
Eliminate links between areas where liquid nitrogen is stored or used and low points (pits, drainage channels,
basements) where it could accumulate and render the atmosphere unbreathable.
-
Use an O
2
concentration detector
to ensure that the oxygen concentration is greater than 18%.
-
Avoid uninsulated liquid nitrogen pipes in any areas.
-
Call on the services of a specialist to determine the layout of facilities.
In case of an incident or accident:
-
If asphyxiation has occurred:
-
Check the oxygen concentration in the room and then take the victim to the open air (taking an
insufflator with you).
-
Start artificial respiration and call the emergency services.
-
In the event of a leak:
-
Evacuate the room.
-
Do not enter the room without breathing apparatus if the oxygen concentration is lower than 18%.
-
Close the valve on the leaking outlet.
-
Aerate the room at length, ensuring that low points are ventilated.
-
If liquid nitrogen is splashed:
-
In the eyes
: rinse the eye thoroughly for at least 20 minutes.
Call a doctor
.
-
On the skin
: do not rub. Remove clothing if necessary. Warm up the affected areas as quickly as
possible under running water for 20 minutes.
Call a doctor
.
2)
Precautions regarding equipment
Warning:
nitrogen is liquid at extremely low temperatures and is stored in a double-walled tank. A high vacuum between
the walls ensures good thermal insulation. This equipment, especially mobile storage tanks, must be handled with care.
-
Avoid impacts. Never lay a cryogenic container on its side.
-
Do not expose containers to excessive temperatures.
-
Treat valves with care (operate gently, do not dismantle or lubricate valves).
-
All equipment used must be in good condition and designed for use at the intended temperature and pressure.
-
Mobile equipment must be sheltered from inclement weather. Open-necked containers must be fitted with
stoppers to avoid the neck becoming blocked by cryopumping of ambient humidity.
-
Use suitable connection hoses; never use intermediate couplings.
-
Monitor the pressure of closed containers and check safety equipment (pressure relief valve).
-
Regulations apply to the transportation of recipients.