NOTICE
Incorrectly Designed Motor and Coupling
Destruction of pump and coupling.
►
Only use motors and couplings that have been adapted to
the pump characteristic curves. If you have any questions,
please contact
Fristam
.
Note: Please see the coupling supplier documentation for refer-
ence dimensions for the coupling.
Procedure
1. Mount the coupling parts on the drive shaft and the gear
shaft.
2. Place the pump on the base frame or the foundation so that
the drive shaft can be connected to the gear shaft with the
coupling.
3. Screw the threaded fastener slightly into the pump base.
4. Check the parallel and angular misalignment of the drive
and gear shafts.
5. Minimize deviations from the angular and shaft misalign-
ment. If necessary, realign or add shims.
6. Screw the pump and gear to the base frame or the founda-
tion.
7. Fasten the coupling according to the coupling manufactur-
er's specifications.
8. Install a noncontact, barrier-providing protective device
(coupling guard) in accordance with Section 1.4, entitled
"Required Characteristics of Guards and Protective Devices,"
of the Machinery Directive 2006/42/EC.
9. The pump is now installed. Do not commission the pump
unless the requirements of the EC Machinery Directive are
met for the complete machine.
Note: Continue with