background image

12

OPERATING INSTRUCTIONS

AIR CONDITIONER FEATURES

Control Panel

A

Swing

B

Display Temperature/Timer

C

PureAir Button

D

Power on·off

F

Fan Speed

G

Adjust Temperature or Timer

H

Mode Selection

E

Dust Filter

J

Timer Indicator

I

Sleep Button

B

A

J

C

I

H

G

F

E

D

Note: “Heat” mode is only for heat and cool models.

OPERATING INSTRUCTION

To change temperature setting

Press the “    ” button to turn the unit ON.
The unit will run in "Cool" mode with a set temperature of 72°F. 
Press the “    ” or “    ” button to choose the temperature in a range of 60°F - 90°F (16°C - 

32°C).

Summary of Contents for FHPC102AC1

Page 1: ... Air Conditioner 13326050000228 July 2019 Introduction 2 Important Safety Instructions 3 Operating Instructions 12 Care and Cleaning 23 Before You Call 24 Major Appliance Limited Warranty 26 Air Conditioner Features 11 Unit Description 7 Accessories Included 7 Installation Instructions 8 ...

Page 2: ...for quick reference If something doesn t seem right the troubleshooting section will help you with common issues FAQs helpful tips and videos cleaning products and kitchen and home accessories are available at www frigidaire com We are here for you Visit our website chat with an agent or call us if you need help We may be able to help you avoid a service visit If you do need service we can get tha...

Page 3: ...ng of your new portable air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded...

Page 4: ... shall be installed in accordance with national wiring regulations Provide ventilation per installation instructions Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively Do not climb on or place objects on the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air conditioner a...

Page 5: ...uids are also suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and Keep ventilation openings clear of obstruction The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance and ignition sourcesor for example an operatin...

Page 6: ...N BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER Unit must be upright for one hour prior to operating The unit should be operated in a temperature range of 60 F 95 F 16 C 35 C when in cool mode and 41 F 90 F 5 C 32 C when in heat mode Performance may be reduced outside of these operating temperatures Operation of Current Device The power supply cord contains a current device that senses damage to th...

Page 7: ...tion of symbols displayed on the unit WARNING This symbol shows that this appliance used a flammable refrigerant If the refrigerant is leaked and exposed to an external ignition source there is a risk of fire This symbol shows that the operation manual should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the installation manual Thi...

Page 8: ...ake sure there s a minimum of 31 5 clearance in the front back of the unit and a minimum of 19 7 clearance in the left right sides of the unit EXHAUSTING HOT AIR 31 5 19 7 Remote Control Safety Lock Bolts Foam seal B Foam seal A Drain hose Drain hose and connector for heat pump model 1 pc Battery 2 pcs 1 pc 2 pcs 1 pc 2 pcs 1 pc 1 set 78 7 2m PARTS PARTS NAME QUANTITY Window Kit Connector A Exhaus...

Page 9: ...of window is less than 26 6 inches Fig 8 Fig 6 Foam seal A adhesive type Fig 7 screws Window slider kit window sill 26 6 52 5 3 Affix the connector A into the window slider kit and seal Fig 3 4 The hose can be extended from its original length of 15 up to 59 but try to maintain the minimum required length Also make sure that the hose does not have any sharp bends or sags Fig 5 Vertical window Wind...

Page 10: ...the height of window Screw down the two screws on the window slider kit See Fig 13 Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig 8 Fig 12 Foam seal A adhesive type Fig 13 window sill Window slider kit screws 26 6 52 5 Fig 10 Fig 9 1 2 screws 3 4 screws or 1 2 hex head cap screws window sill Window slider kit 7 Cut the non adhesive foam seal B to an appro...

Page 11: ...eal B Fig 16 7 To secure sliding sash in place attach right angle sash lock with 1 2 12 7mm screw as shown Fig 16 3 Close the window sash securely against the window slider kit Fig 14 4 Drive two 1 2 screws to secure the window slider kit to the window sash Fig 14 5 Drive two 3 4 screws to secure the window slider kit to the window sill Fig 14 Fig 14 window sill Window slider kit 3 4 screws 1 2 sc...

Page 12: ... Timer H Mode Selection E Dust Filter J Timer Indicator I Sleep Button B A J C I H G F E D Note Heat mode is only for heat and cool models OPERATING INSTRUCTION To change temperature setting Press the button to turn the unit ON The unit will run in Cool mode with a set temperature of 72 F Press the or button to choose the temperature in a range of 60 F 90 F 16 C 32 C ...

Page 13: ...n speed according to the illumination of the fan speed indicator You can choose the Auto Lo Med or Hi fan speed setting Press the or button to choose the temperature you want Dry mode Press the Mode button until the Dry mode indicator lights up In this mode the or button is disabled and the screen displays the room temperature The unit will continuously drain moisture from the room Note In this mo...

Page 14: ...leep Mode Fan speed or button Note In Fan or Dry mode Sleep mode cannot be set During Sleep mode the brightness of the indicators will reduce by half Auto mode Press the Mode button until the Auto mode indicator lights up Press the or button to choose the temperature you want The screen will display the temperature setting In this mode the unit will automatically select cooling or fan only operati...

Page 15: ...sly set Press the Timer button again within 5 seconds you will exit the timer settings To cancel the setting press the Timer button again It will show the remaining time Press the button again to exit this function Dust filter reset This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The Clean indicator will illuminate after 250 hours of fan operat...

Page 16: ...n speed indicator You can choose the Hi Med Lo or Auto fan speed setting Note In this mode the air exhaust hose need to be connected Note The unit has a built in condensate pump to pump out the excess condensate during heating mode Condensate drainage is required refer to the Drainage Instructions on Page 21 for more instructions to drain the excess condensate How to delay shutdown You can delay s...

Page 17: ...t Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries Do not dispose of batteries in fire Batteries may explode or leak If the remote control is not used for a long time remove the batteries from the remote control The remote control must be handled with extreme care Do not drop it or expose it to direct sunlight or sources of heat If ...

Page 18: ...isplays cool Press the speed button to choose the fan speed auto high mid and low Press the and button to choose the temperature you want Cool mode Press the mode button until the left side of LCD screen displays fan In this mode you can select fan speed high mid low by pressing the Fan speed button and referring to the diagram Note In this mode the air exhaust hose does not need to be connected F...

Page 19: ...ease by another 2 F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep mode fan speed or on off button Note In Fan or Dry mode Sleep...

Page 20: ... will display timer and h and off will flash Tap or hold the UP arrow or the DOWN arrow to change delay shutdown timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours After 3 seconds the timer function is enabled then off will stop flashing the display will show the temperature and the control will count down the time remaining until shutdown To cancel the setting pr...

Page 21: ...nscrew the drain cap of continuous drain outlet Fig 20 Connect one end of the garden hose sold separately to the drain outlet then lead the other end into a drain that is lower than the unit Fig 21 Drain cap for Dry mode Figure 20 NOTE Condensate may flow out after removing the drain cap if the unit is running in Cool or Auto mode When you want to remove the garden hose prepare a drip tray not sup...

Page 22: ...e has been removed tilt the unit by lifting it slightly upwards from the front until no more condensate comes out from the drain outlet Put a drip tray not supplied under the continuous drain outlet then unscrew the drain cap to allow the condensate to flow into the drip tray Replace the drain cap to the continuous drain outlet when no condensate flows out Put the drip tray under the bottom drain ...

Page 23: ...rol 4 Store the air conditioner in a cool dry location away from direct sunlight extreme temperature and excessive dust Before using the air conditioner again 1 Make sure the filter and drain cap are in place 2 Check the cord to make sure it is in good condition without cracks or damage 3 Place new batteries in the remote control 4 Install the air conditioner as described in the Installation Instr...

Page 24: ...ature rises above 60 F 16 C Reset to a lower temperature Compressor shut off by changing modes Wait approximately 4 minutes and listen for compressor to restart when set in the COOL mode Before calling for service review this list It may save you time and expense This list includes common occurrences that are not the result of defective workmanship or materials in this appliance SOLUTION OCCURRENCE...

Page 25: ...om too cold Set temperature too low Increase set temperature Room too hot Set temperature too high Lower setting If These Solutions Fail Call 1 800 944 9044 US 1 800 265 8352 Canada For Frigidaire Service 25 BEFORE YOU CALL ...

Page 26: ...ntacting Electrolux at the addresses or phone numbers below This limited warranty only applies in the USA and Canada In the USA your appliance is warranted by Electrolux Major Appliances North America a division of Electrolux Home Products Inc In Canada your appliance is warranted by Electrolux Canada Corp Electrolux authorizes no person to change or add to any obligations under this warranty Obli...

Page 27: ......

Page 28: ...aire com 1 800 944 9044 Frigidaire ca 1 800 265 8352 owner support accessories service Our home is your home Visit us if you need help with any of these things registration See your registration card for more information ...

Reviews: