background image

GAS WALL OVEN INSTALLATION INSTRUCTIONS

8

Observe the oven burner flame to determine if it is right.
It should be steady with a blue cone approximately 1"
and should not extend out over the edges of baffle.  For
LP Gas, this will most likely occur when the air
adjustment shutter is completely open (see figure 15).
Turn Oven Temperature to 300°F and allow oven to cycle
on and off.

To replace broiler drawer or lower bottom, reverse steps
taken for removal.  Replace oven rack and/or broiler
pan.

12. Check Operation

Refer to the Use and Care Guide packaged with the wall
oven for operating instructions and for care and cleaning
of your appliance.

Do not touch the oven burner.  They may be hot enough
to cause burns.

1.

Check the Igniters (some models)

Operation of electric igniters should be checked after
oven and supply line connectors have been carefully
checked for leaks and oven has been connected to
electric power.

2.

Oven Igniter System

Close the door and turn the Oven Temperature to
300°F.  In approximately 60 seconds, the burner
should ignite and stay on until oven reaches 300°F.
Burner should then cycle on and off to maintain an
average temperature of approximately 300°F.

When All Hookups are Complete

Make sure all controls and programmable timer are left in
the OFF position.
Reset all controls to the "OFF" position after using a
programmable timing operation.

Model and Serial Number Location

The serial plate is located on the left side inner trim of
the oven for the model with 1 ½ oven cavity and on the
lower oven frame for the model with 2 oven cavities.
When ordering parts for or making inquires about your
wall oven, always be sure to include the model and
serial numbers and a lot number or letter from the serial
plate of your appliance.

Your serial plate also tells you the rating of the burners,
the type of fuel and the pressure the wall oven was
adjusted for when it left the factory.

 

 Stepping, leaning or sitting on the

oven door or drawer can result in serious injuries
and also cause damage to the appliance.

Be sure to keep appliance clear of combustible
materials, gasoline and other flammable vapors and
liquids.

Before You Call for Service

Read the Avoid Service Checklist and operating and
cleaning instructions in your Use and Care Guide.

Check to make sure the house fuse or circuit breaker for
your wall oven is not blown or open.

Care, Cleaning and Maintenance for Wall
Ovens

If removing the wall oven is necessary for cleaning or
maintenance, shut off gas supply.  Disconnect the gas
and electric supply.  Remove the installation screws from
front frame and lower trim.  Pull out only as far as
necessary to disconnect the electric supply line.  After
disconnecting the gas and electric supply, finish
removing the unit for servicing and cleaning.  Reinstall in
reverse order making sure to level the appliance; check
gas connection for leaks.

Figure 15

Summary of Contents for FGB24T3ESC

Page 1: ...y a qualified installer service agency or the gas supplier NOTE Wiring diagrams for these appliances are enclosed in this booklet P N 318201554 0503 Rev A English pages 1 8 Español páginas 9 16 Wiring Diagram pages 17 20 Figure 1 Additional Safeguards Do not install wall oven beneath the work counter The flue charge shall not be located below the 36 level Clearance for complete door opening For mo...

Page 2: ... Refer to figure 1 for the dimensions applicable to your appliance and the space necessary to receive the oven Corners must be square Floor cabinet must be able to support 150 pounds and must be flush with bottom of opening Bricked opening for model with 2 cavities only If oven is to be installed in brick or stone first construct a rectangular wooden frame with sides and top and bottom The inside ...

Page 3: ...ernal electrical source is used the appliance when installed must be electrically grounded in accordance with local codes or in their absence of local codes with the National Electric Code ANSI NFPA No 70 1987 or latest edition Check all code rules and regulations for connecting the wall oven to be certain the installation conforms with all local municipal and state codes as well as local utility ...

Page 4: ...h 1 oven cavity only Remove and lay aside the lower vent decorative trim that is taped to the side or to the top of the oven The decorative trim will be fastened to the lower front of the oven after it has been installed in the cabinet There is a 1 height adjustment on models with extension panel see figure 4 With this adjustment and a trim overhang a unit can be installed in existing openings 37 ...

Page 5: ...he unit on and off The gas supply line to the unit should be 1 3 cm or 1 9 cm pipe To avoid pilot outage if applicable close all openings in the cabinet cavity that encloses this unit All openings around gas service outlets must be closed at the time of installation 6 Externally Vented Installations Model With 2 Oven Cavities only IMPORTANT Refer to the serial plate for information on type of vent...

Page 6: ... gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 9 LP Propane Gas Conversion A Pressure Regulator Conversion Note Do not remove the Pressure Regulator Convert the Pressure Regulator for use with LP Gas see figure 11 If applicable remove broiler or storage drawer by pulli...

Page 7: ... tube which sets on the hood of the valve and is locked in place with a Phillips head screw If the air shutter needs adjusting loosen the screw and rotate the shutter to allow more or less air to the burner tube see figure 14 Gasket SMALL End Towards Regulator For Natural Gas ENLARGED End Towards Regulator For L P Gas Figure 11 For Natural Gas the air shutter should be approximately half open For ...

Page 8: ...a programmable timing operation Model and Serial Number Location The serial plate is located on the left side inner trim of the oven for the model with 1 oven cavity and on the lower oven frame for the model with 2 oven cavities When ordering parts for or making inquires about your wall oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate of ...

Page 9: ...RTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR ELÉCTRICO LOCAL LEA Y GUARDE ESTAS INSTRUCCIONES PARA FUTURAS REFERENCIAS Si todas las instrucciones de éste manual no son observadas a la letra se puede ocurrir incendios o explosiones que pueden causar daños materiales lesiones o la muerte PARA SU SEGURIDAD No almacene o utilice gasolina u otros vapores y líquidos inflamables cerca de éste...

Page 10: ...rio en el que poner el horno Las esquinas deben estar cuadradas El piso del gabinete debe soportar una carga de 150 libras y debe estar nivelado con el fondo de la abertura Abertura en ladrillo para modelo con 2 cavidades del mismo tamaño solamente Si el horno va a ser empotrado en ladrillo o piedra construya primero un marco rectangular de madera de en las laterales y arriba y abajo Las dimension...

Page 11: ...instalación está de acuerdo a los códigos locales estatales y de las empresas de servicio de energía locales El incumplimiento las anteriores recomendaciones puede resultar en un peligroso coque eléctrico Nota Todas las conexiones y ajustes deben de ser realizados por un técnico calificado Desconecte el cable del suministro eléctrico del enchufe de pared antes de reparar la plancha de cocinar 3 Al...

Page 12: ...ornillos para fijar la parte delantera del artefacto al gabinete etapa 1 aquí abajo Guarde los tornilos decorativos para fijar el marco al gabinete etapa 2 aquí abajo Los hoyos de montage en la parte delantera del artefacto pueden ser utilizados como referencia para localizar los hoyos de montaje en el gabinete Para ajustar el artefacto al gabinete figura 6 1 Utilize los 4 tornilos de montaje para...

Page 13: ...tilación B Ajuste la tubería de ventilación a la salida de ventila ción con un tornillo ver figura 8 Para ajustar el tubo a la salida es necesario remover el panel de controles para poder alcanzar el tornillo Guarde al menos 1 de margen libre entre la tubería de ventilación y los elementos combustibles vecinos como lo establece la placa de serie Remueva tornillo A Capucha Tubo para fijar a salida ...

Page 14: ... ningún tipo de llama para verificar si hay fugas de gas Verifique si hay fugas con una llama puede ocasionar incendio o explosión Desconecte el horno y su válvula de cierre individual del sistema de tubería del suministro de gas durante cualquier ensayo de presión del sistema en ensayos de presión superiores a 1 2 psig 3 5 kPa o 14 colomna de agua Aparte el horno del sistema de tubería del sumini...

Page 15: ... en su lugar por un tornillo con cabeza tipo Phillips Si éste necesita ajuste afloje el tornillo y rota el obturador para permitir más o menos aire en el tubo del quemador vea figura 14 Figura 13 L P Nat Junta en forma de bellota de la parilla Pasador Junta en forma de bellota Obturador de aire Usando una llave de giro hacia abajo la junta en forma de bellota ajustable que inyecta gas al quemador ...

Page 16: ... la lista titulada Evitando Llamadas de Servicio y las instrucciones de functionamiento en su Manual del Usuario Verifique que los fusibles de la casa no se hayan fundido o el cortocircuito del horno no haya saltado o abierto Cuidado limpieza y mantenimiento Cierre el suministro de gas en caso de ser necesario remover la unidad para su limpieza o reparación Desconecte la línea de suministro de gas...

Page 17: ...17 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For Models with 2 Oven Cavities Para modelo con 2 cavidades ...

Page 18: ...18 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For 2 and 1 Oven Cavities with Electronic Oven Control Models Para modelos con 2 o 1 cavidades con controles electrónicos del horno ...

Page 19: ...19 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For Self Clean Models with 1 Oven Cavity Para modelos auto limpiables con 1 cavidad ...

Page 20: ...20 NOTES NOTAS ...

Reviews: