READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &
press RESET

The power supply cord contains a current device that senses damage to the power cord. To test 
your power supply cord do the following:

Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESET button pops out.

Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (This is also indicated by a light 
on the plug head).

SAFETY PRECAUTIONS

Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make 
units run excessively.
Do not climb on or place objects on outdoor part of the unit.
Do not hang objects off the unit.
Do not place containers with liquids on the unit.
Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit’s installation accessories for any damage.
Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place.
Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit.
Do not use or store flammable gases near the unit. 
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
When cleaning the unit, first make sure that the power and circuit breaker are turned off.

NOTE:

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.

If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained
from the product manufacturer.

CAUTION!  Avoid Injury or damage to the unit or other property 

Summary of Contents for FFRE1533Q1

Page 1: ...2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 11 of your Room Air Conditioner Before You Call 12 Major Appliance Limited Warranty 13 www frigidaire com USA 1 800 944 9044 www frigidaire ca Canada 1 800 265 8352 ...

Page 2: ... run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord NOTE The power supply cord with this air conditioner con...

Page 3: ...wer source when it will not be used for an extended period of time Periodically check the condition of the unit s installation accessories for any damage Do not apply heavy pressure to the radiator fins of the unit Operate the unit with air filter in place Do not block or cover the intake grille discharge area and outlet ports Ensure that any electrical electronic equipment is one yard away from t...

Page 4: ...ushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 4 Product Registration Packaging Normal Sounds 2009 Electrolux Home Products Inc All rights reserved Packaging Remove all packaging from inside the carton along ...

Page 5: ...ng Instructions ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER CHECK FILTER RESET BUTTON SLEEP MODE REMOTE TEMP SENSING INDICATOR some models CLEAN AIR FEATURE some models STANDARD REMOTE w DISPLAY REMOTE SENSING BUTTON FOR HEAT MODELS Battery Size AAA Warning Do not mix old and new batteries Do not mix alkaline standard carbon z...

Page 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and ...

Page 7: ...operate as originally programmed The Sleep mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling ...

Page 8: ...p to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling with maximum Fan speed if Cool Energy Saver or Fan Only was the last mode selected The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the ...

Page 9: ...until the feature is deactivated by pressing the remote sensing Stop button lf the unit does not receive the remote sensing signal during any 3 minute interval the unit will beep to indicate the remote sensing mode has ended The display on the remote control indicates the temperature at the remote ONLY NOTE The Remote Sensing function is terminated either by using the Remote Sensing Stop button or...

Page 10: ...and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY HEAT This is to cover the possibility of having to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the...

Page 11: ...to the installation instructions Cover it with plastic or return it to the original carton NOTE When replacing the air filter after cleaning make sure the tabs on the air filter are on the upper part of filter and placed outward as shown in the drawing on the left side Air Filter Tab Energy Saving Ideas Do not block air flow inside with blinds curtains or furniture or outside with shrubs enclosure...

Page 12: ...defrost the coil set to FAN ONLY mode Then set temperature to a higher setting 12 Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen f...

Page 13: ...IS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servi...