Installation of the housing
Flash or seal around external
wall frame or architrave
Sturdy timber
frame all round unit
Drain pan
External support frame at
balance point of air conditioner.
Timber framed
wall or partition
Alternatively, brackets as illustrated
below may be used.
Preferred method of installation into a timber
framed wall, partition or window.
Step 1:
Remove the air conditioner from it's packaging, remove fixing screws
and slide the air conditioner out of it's housing (Refer to Installation
Steps).
Step 2:
Prepare the hole in the wall so that the bottom of the housing is well
supported, the top has minimum clearance and the air inlet louvers
have clearance as shown below in options A and B. Holes from the
outside through to the cavity should be sealed. The housing should
slope down towards the rear by about 5mm to allow water formed
during operation to drain.
Step 3:
Install the housing into the wall and secure. Ensure the foam seals are
not damaged. Flash, seal or fill gaps around the inside and outside to
provide satisfactory appearance and protection against the weather,
insects and rodents.
Step 1:
Slide the unit into the housing until it is firmly against the rear of the
housing. Care is required to ensure the foam sealing strips on the
housing remain in position.
Step 2:
Connect the air conditioner to the power and position
excess cord
length beneath the air conditioner base.
Installation of the unit into the housing
Step 3:
Engage the chassis fixing brackets into the bottom housing
rail and
secure to the base with the screw provided.
Step 4:
Remove the front panel from it's carton and plastic bag
and fit as per
the Installation lnstruction.
Step 5:
Switch unit on. Check for operation of the unit and check
for vibration in
the installation.
Step 6:
Fit the drain pan to the housing and run a drain line to a
suitable
location if required.
Installations of the unit into the wall
Air out
100mm
100mm
Wall
OPTION B
OPTION A
100mm
Air in
Air out
Air in
Flash or seal around external
wall frame or architrave
Drain pan
Timber framed
wall or partition
Sturdy
timber frame
Steadying bracket
(one per side)
Solid timber support
Ensure louvres are
entirely outside the wall
Alternative method of installation if external
support cannot be provided.
Air in
Air in
Air in
Air out
Wall
45° brick cut away
To clear louvres
E
N
G
E
N
G
45