background image

ROOM AIR CONDITIONER WARRANTY

Your product is protected by this warranty

Frigidaire
P.O. Box 212378
Augusta, GA 30917

800-444-4944

*NORMAL
RESPONSIBILITIES
OF THE CONSUMER

EXCLUSIONS

IF YOU NEED SERVICE

FULL ONE-YEAR
WARRANTY

LIMITED 2-5 YEAR
WARRANTY (Sealed

LIMITED WARRANTY
(Applicable to the 

WARRANTY

THE CONSUMER WILL BE 

RESPONSIBLE FOR:

Costs of service calls that are listed under

NORMAL  RESPONSIBILITIES OF  THE
CONSUMER.*

Diagnostic    costs    and   any   removal,
transportation  and  reinstallation  costs
which are required because of service. 
Costs for labor, parts and transportation 
other  than  with  respect  to  the  Sealed 
Refrigeration System.

Costs  of  the  technician’s  travel  to  the 
home   and   any  costs  for  pick  up  and 
delivery    of    the    appliance    required 
because of service.

One year from original
purchase date.

Second   through   fifth
years   from   original

Time    periods   listed
above.

Pay all costs for repairing or replacing 
parts of this appliance which prove to be 
defective in materials or workmanship.

Repair or replace any parts in the Sealed
R e f r i g e r a t i o n   S y s t e m   ( c o m p r e s s o r,
c o n d e n s e r ,   e v a p o r a t o r  a n d   t u b i n g )  
proves to be defective in materials or 

All of the provisions of the full and limited
warranties   above   and   the  exclusions 
listed below apply.

    FRIGIDAIRE, THROUGH  ITS
AUTHORIZED SERVICERS, WILL

This   warranty   applies   only   to   products  in  ordinary  household  use,  and  the  consumer  is 
responsible for the items listed below.

1. Proper use of the appliance in accordance with instructions provided with the product.
2. Proper  installation  by  an  authorized  servicer  in  accordance  with  instructions  provided  with  the 
    appliance and  in accordance with all local plumbing, electrical and/or gas codes.
3. Proper  connection  to  a  grounded  power  supply  of sufficient  voltage, replacement of blown fuses, 
    repair of loose  connections or defects in house wiring.
4. Expenses  for  making  the  appliance  accessible  for  servicing,  such as removal of trim, cupboards, 
    shelves, etc.,  which are not a part of the appliance when it was shipped from the factory.
5. Damages to finish after installation.

This warranty does not cover the following:

1. CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL
     EXPENSES  RESULTING  FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY. 
     Note: Some states do not allow the exclusion or limitation of incidental or consequential damages, so 
     this  limitation or exclusion may not apply to you.
2. Service calls which do not involve malfunction or defects in workmanship or material, or for appliances 
    not in ordinary household use. The consumer shall pay for such service calls.
3. Damages caused by services  performed by  persons  other  than authorized Frigidaire servicers; use 
    of  parts  other   than  Frigidaire  Genuine  Renewal   Parts;  obtained  from persons  other  than  such 
    servicers; or external causes  such as abuse, misuse, inadequate power supply or acts of God.
4. Products  with  original  serial  numbers  that  have  been  removed  or  altered  and  cannot be readily 
    determined. 

Keep  your  bill  of  sale,  delivery  slip, or  some  other  appropriate  payment record. The date on the bill 
establishes  the  warranty  period  should  service  be required.  If service  is performed, it is in your best 
interest  to  obtain  and  keep  all receipts. This  written warranty gives you specific legal rights. You may 
also have  other  rights  that  vary  from  state  to state. Service  under this warranty must be obtained by 
following these steps, in order:
1. Contact Frigidaire Consumer Services or an authorized Frigidaire servicer.
2. If there is a question as to where to obtain service, contact our Consumer Relations Department at:

 

Product features or specifications as described or illustrated are subject to change without notice. All warranties are made by Electrolux.
This warranty applies only in the 50 states of the U.S.A., Puerto Rico and Canada.

 2

Your appliance is warranted by Electrolux. Electrolux has authorized Frigidaire Consumer Services and their authorized servicers to 
perform service under this

 

warranty. Electrolux authorizes no one else to change or add to any of these obligations under this 

warranty. Any obligations for service and parts under this

 

warranty must be performed by Frigidaire Consumer Services or an 

authorized Frigidaire servicer.

system)

State of Alaska)

purchase date.

workmanship.

Summary of Contents for FAK127P1V

Page 1: ...RE MANUAL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER 3 SPEED ELECTRONIC CONTROL P N819042059 01 ...

Page 2: ...sh after installation This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY Note Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you 2 Service calls which do not invo...

Page 3: ...ooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through the evaporator during normal operation Pinging or Swishing Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Product Registration Co...

Page 4: ...To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug and a current leakage detection device for protection against shock fire hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker...

Page 5: ...upply cord must be replaced if it fails to reset when either the TEST button is pushed or it can not be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel ...

Page 6: ...utton until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 60 F 15 C and 90 F 32 C If you want the display to read the actual room temperature See To Operate on Fan Only section on Page 7 TO ADJUST FAN SPEEDS YOU WILL SEE DO THIS PRESS TO SELECT LOW MED or HIGH The chosen fan speed LED will light up Temp Timer Temp Timer Fan Fan Te...

Page 7: ...RGY SAVER FEATURE YOU WILL SEE DO THIS PRESS MODE BUTTON CHOOSE ENERGY SAVER NOTE In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor turns back on and cooling starts NOTE Fan starts at High Speed and adjusts to a slower...

Page 8: ...can be cancelled at any time during operation by again pressing the Sleep button CHECK FILTER FEATURE YOU WILL SEE NOTE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off NOTE For Delay Stop the unit...

Page 9: ...ust Control allows the air conditioner to either recirculate inside air CLOSED or exhaust air to the outside OPEN The CLOSED position is used when maximum cooling is desired It may also be used for air recirculation without cooling when the air conditioner is set in any FAN position The OPEN position removes stale air from the room and exhausts it to the outside Fresh air is drawn in through norma...

Page 10: ...binet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaner wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the...

Page 11: ... temperature to a lower number Current device tripped Preset RESET button Reset to a lower temperature Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Exhaust set at OPEN position Set exhaust at CLOSED position for maximum cooling Air direction louvers positioned improperly Position louvers for better air distributio...

Reviews: