background image

Important Safety Instructions

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &
press RESET

The power supply cord contains a current device that senses damage to the power cord. To test 
your power supply cord do the following:

Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESET button pops out.

Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (On some products this is also indi-
cated by a light on the plug head).

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings. 

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following: 

Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation. 

Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the 
installation instructions for possible future use in removing or reinstalling this unit. 

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements. 

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.  

Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.  

Do not use an extension cord or an adapter plug.

WARNING

Electrical Information

WARNING

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.

NOTE:

The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.

NOTE:

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.

If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained
from the product manufacturer.

2

2009 Electrolux Home Products, Inc.

All rights reserved.

NOTE:

This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as 
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that 
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 

115V

15A

230V

15A

230V

20A

Do not, under any
circumstances, cut, 
remove or bypass the 
grounding prong.

230V

30A

Grounding Prong

Summary of Contents for B00IYQSMU2

Page 1: ...8352 All about the Use Care 9 Care and Cleaning 9 Energy Saving Ideas 2020213A0495 June 2009 Product Registration 3 Normal Sounds 3 Air Conditioner Features 4 Important Safety Instructions 2 Operating Instructions 4 9 Before You Call 10 Major Appliance Warranty 11 of your Room Air Conditioner ...

Page 2: ...g when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or ...

Page 3: ...er during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gur...

Page 4: ...eserved ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER CHECK FILTER RESET BUTTON REMOTE TEMP SENSING INDICATOR some models SLEEP MODE w DISPLAY REMOTE SENSING BUTTON FOR HEAT MODELS Battery Size AAA Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries PRESS ON ...

Page 5: ...OWER PRESS TO RAISE Note Tap or hold either up or down button until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C for cooling mode The temperature will be auto matically maintained anywhere between 55 F 13 C and 80 F 27 C for heating mode If you want the display to read the actual room temperature See To Op...

Page 6: ...ed if Cool Energy Saver or Fan Only was the last mode selected or heating with maximum Fan speed if Heat was the last mode selected Note On 115V models only low speed can be selected The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the control will ...

Page 7: ...N OFF button on the unit 7 Operating Instructions Operating Instructions continued 2009 Electrolux Home Products Inc All rights reserved CHECK FILTER FEATURE YOU WILL SEE Note This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light Will illuminate after 250 hours of operation To reset after cleaning the filter press the Filter Reset butto...

Page 8: ...s a 2 Second delay for the compressor shutting down when selecting FAN ONLY HEAT This is to cover the possibility of having to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored FAULT CODES If the display reads HS a sensor has failed Contact your Authorized Frigidaire Service Center If the ...

Page 9: ...ont may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air c...

Page 10: ... located within range Place remote control within 20 feet 120 radius of the front of the unit If These Solutions Fail Call 1 800 944 9044 For Frigidaire Service Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty Clean filter Refer to Ca...

Page 11: ...pliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER ...