7. The dryer 

MUST

 be isolated from the gas supply piping system

during any pressure testing of the gas supply piping system at test
pressures equal to or less than
1/2 psig (3.45 kPa).

                    LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:

1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or

anything that will obstruct the flow of combustion and ventilation air.

3. On carpet. Floor 

MUST

 be solid with a maximum slope of 1 inch (2.54

cm).

INSTALLATION IN RECESS OR CLOSET

1. A dryer installed in a bedroom, bathroom, recess or closet, 

MUST

 be

exhausted outdoors.

2. No other fuel burning appliance shall be installed in the same closet

as the Gas dryer.

3. Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4. A minimum of 120 square inches (774.2 square cm) of opening,

equally divided at the top and bottom of the door, is required. Air
openings are required to be unobstructed when a door is installed. A
louvered door with equivalent air openings for the full length of the
door is acceptable.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)
                SIDES        REAR          TOP           FRONT

Alcove

0  (0  cm)     0  (0  cm)      0 (0 cm)

Closet

0  (0  cm)   0 (0 cm)      0 (0 cm)       1 (2.54 cm)

Closet door ventilation required:  2 louvered openings each 60 square
inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and
top of door.

This dryer MUST be exhausted outdoors.

5. The following illustrations show minimum clearance dimensions for

proper operation in a recess or closet installation.

In installations where the exhaust system is not described in the charts,
the following method must be used to determine if the exhaust system is
acceptable:
1. Connect an inclined or digital manometer between the dryer and the

point the exhaust connects to the dryer.

2. Set the dryer timer and temperature to air fluff (cool down) and start

the dryer.

3. Read the measurement on the manometer.
4. The system back pressure 

MUST NOT

 be higher than 0.75 inches of

water column.  If the system back pressure is less than 0.75 inches
of water column, the system is acceptable.  If the manometer reading
is higher than 0.75 inches of water column, the system is too
restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is acceptable, certain
extenuating circumstances could affect the performance of the dryer:

Only the rigid metal duct work should be used.

Venting vertical through a roof may expose the exhaust system
to down drafts causing an increase in vent restriction.

Running the exhaust system through an uninsulated area may
cause condensation and faster accumulation of lint.

Compression or crimping of the exhaust system will cause an
increase in vent restriction.

The exhaust system should be inspected and cleaned a minimum of

every 18 months 

with normal usage.  The more the dryer is used, the

more often you should check the exhaust system and vent hood for
proper operation.

EXHAUST DIRECTION

All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or left side of
the cabinet or the bottom of the dryer. On gas dryers, exhausting can be
to the right side of the cabinet or the bottom of the dryer. Directional
exhausting can be accomplished by installing Exhaust Kit, P/N
131456800, available through your parts distributor. Follow the
instructions supplied with the kit.

INSTALL MALE FITTINGS IN CORRECT DIRECTION

CORRECT

INCORRECT

GAS SUPPLY REQUIREMENTS

Replace copper connecting pipe that is not

plastic-coated. Stainless steel or plastic-coated brass MUST be
u s e d .

1. Installation 

MUST

 conform with local codes, or in the absence of

local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest
edition).

2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect your

dryer to the gas supply line. The tubing 

MUST

 be constructed of

stainless steel or plastic-coated brass.

4. The gas supply line 

MUST 

have an individual shutoff valve.

5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test

gauge connection, 

MUST

 be installed immediately upstream of the

gas supply connection to the dryer.

6. The dryer 

MUST

 be disconnected from the gas supply piping

system during any pressure testing of the gas supply piping system
at test pressures in excess of 1/2 psig (3.45 kPa).

EXHAUST DUCT LOCATING DIMENSIONS

CLOSET DOOR

60 sq. inches
(387.1 sq. cm)

60 sq. inches
(387.1 sq. cm)

0" (0 cm)

0" (0 cm)

0" (0  cm)

1" (2.54 cm)

Summary of Contents for AEQ6000CES0

Page 1: ...nte du Code ANSI NFPA 70 ou au Canada le Code canadien d électricité ACNOR C22 1 partie1 REMARQUE L alimentation en gaz de la sécheuse doit respecter les codes et ordonnances locaux ainsi que l édition la plus récente du Code ANSI Z223 1 ou au Canada le code CAN ACG B149 1 2000 REMARQUE La sécheuse est conçue conformément au code ANSI Z 21 5 1 ou ANSI UL 2158 CAN ACG C22 2 No 112 l édition la plus...

Page 2: ...receptacle to be located so the power supply cord is accessible when the dryer is in the installed position NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer...

Page 3: ...column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer Only the rigid metal d...

Page 4: ...1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 27 68 58 5 13 97 29 75 57 13 34 29 5 12 70 2 6 03 3 8 34 86 36 35 88 90 2 25 5 72 Stacked Dryer Installation Dimensions To front of cabinet 28 25 71 76 To clear kobs 28 75 73 03 To clear door 29 5 74 93 To clear open door 53 134 62 13 5 34 29 27 68 58 Ele...

Page 5: ... MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your dealer 5 R...

Page 6: ...s in reverse order 10 Close the door Be sure to wear gloves while reversing the door assembly 1 2 6 3 4 5 7 1 Open the dryer door 2 Remove the five screws 1 thru 5 and the two screws 6 and 7 that attach the inner door assembly to the outer door assembly Lift the outer door assembly out of the inner door assembly and place on a soft flat surface 3 Remove the two 2 hinge attachment screws and place ...

Page 7: ... 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are ...

Page 8: ...gs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating a...

Page 9: ...etl entrée d insectes ou de rongeurs Afin de ne pas obstruer l évacuation de l air laisser une distance minimum de 30 5 cm 12 po entre la grille de sortie et le sol ou tout autre obstacle Les mises en garde qui suivent se rapportent directement au fonctionnement correct et sécuritaire de la sécheuse Toute dérogation à ces mises en garde pourrait ralentir le séchage et entraîner des risques d incen...

Page 10: ...on et ainsi réduire la capacité d évacuation du circuit Un circuit d évacuation comprimé ou ondulant peut voir sa capacité d évacuation réduite Il faut inspecter le circuit d évacuation et le nettoyer au moins à tous les 18 mois d utilisation normale Plus la sécheuse est utilisée plus il faut procéder souvent à une vérification du bon fonctionnement du circuit d évacuation et du couvercle du regis...

Page 11: ...ENT DE LA SÉCHEUSE EMPLACEMENT DE LA SÉCHEUSE NE PAS INSTALLER LA SÉCHEUSE 1 Dans un endroit exposé à un écoulement d eau ou aux conditions atmosphériques 2 Dansunendroitoùelleseraitencontactavecdesrideaux draperies ou tout ce qui obstruera le flux d air de combustion et de ventilation 3 Sur un tapis Le plancher DOIT être ferme et présenter une pente de 2 54 cm 1 po au maximum INSTALLATION DANS UN...

Page 12: ...e coffret 28 25 71 76 Aux boutons clairs 28 75 73 03 À la poignée claire de porte 29 5 74 93 À l espace libre ouvrez la porte 53 134 62 13 5 34 29 27 68 58 Alimentation électrique sur l arrière de l unité 2 375 6 03 Pipe d offre de gaz sur l arrière de l unité 72 00 172 88 38 25 97 16 41 00 97 16 Ligne taille centrale pour arrière droit parti passage 4 375 11 12 Echappements Latéraux 15 8 4 13 25 ...

Page 13: ...5 Se référer aux pages 2 et 3 pour de plus amples informations ur les exigences de ventilation 6 L installation DOIT respecter la norme fédérale sur la construction etlasécuritédesmaisonsmobilesenvigueur ManufacturedHome Construction Safety Standard partie intégrante du règlement fédéral 24 CFR Partie 32 80 ou lorsque cette norme ne s applique pas elle doit respecter la norme nationale américaine ...

Page 14: ...ez la porte Assurez vous de porter des gants lors de l inversion de la porte 1 2 6 3 4 5 7 1 Ouvrez la pote 2 Démontez les cinq vis 1 à 5 et les deux vis 6 et 7 qui fixent la contre porte à la partie extérieure de la porte Soulevez la partie extérieure hors de la contre porte et couchez la sur une surface plate et douce au toucher 3 Démontez les deux 2 vis de fixation de la penture et couchez la c...

Page 15: ... cordon de rallonge avec cette sécheuse Certains cordons de rallonge ne sont pas conçus pour supporter l intensité du courant qu utilise cette sécheuse ils peuvent fondre et présenter un risque choc électrique ou d incendie Placer la sécheuse à portée de la prise murale afin de déterminer la longueur du cordon à acheter et prévoir un certain jeu dans la longueur du cordon Se reporter à la section ...

Page 16: ...euse pour la facilité d utilisation Le manque d utiliser des accessoires certifiés par le fabricant a pu avoir comme conséquence des blessures des dommages matériels ou des dommages à la sécheuse Si vous désirez des pièces de remplacement pour votre machine à laver communiquez avec le numéro sans frais de Service et pièces de Frigidaire CompanyAuthorizedPartsDistributor 1 800 944 9044 ouvisiteznot...

Reviews: