background image

4

   

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any cir-
cumstances, cut, re-
move, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Read all instructions before using this air conditioner.

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen. This information

can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

• If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.

• Be sure the air conditioner has been securely and correctly installed according to the

separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.

• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front

and rear coils.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay
fuse or circuit breaker, have a qualified electrician install the proper receptacle.

• Do not run air conditioner with outside protective cover in place. This could result in

mechanical damage within the air conditioner.

• Do not use an extension cord or an adapter plug.

Important Safety
Instructions

The power supply cord with

this air conditioner contains a current de-
tection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired it must be
replaced with a cord from the Product Manu-
facturer.

Operation of Current
Device

The  power supply cord contains a current device that senses damage to the power cord. To
test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button.

You will notice a click as the RESET button pops out.

3. Press the RESET button. Again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is

also indicated by a light on the plug head).

NOTES:

• Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
• The power supply cord must be replaced if it fails to reset when either the TEST button is

pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.

• If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one

obtained from the product manufacturer.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Plug in & 
press RESET

SZ000710(En)-JiXie

2005.9.13, 11:04 AM

4

Summary of Contents for 220201d051

Page 1: ...1 USE CARE MANUAL ROTARY CONTROL AIR CONDITIONER ...

Page 2: ...n house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES...

Page 3: ...r Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal operati...

Page 4: ...g is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with ou...

Page 5: ...e If your unit is equipped with a vent handle keep it closed for maximum efficiency Fan Mode Rotate the knob to the left to select your choice of fan speeds for air circulation Note When selecting a fan speed the compressor will not run On models with a vent control this mode can be used to remove stale air from the room or to draw fresh air into the room Check the section Additional Things You Sh...

Page 6: ...louvers until the desired Up Down direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you should become familiar with Figure 1 VENT CLOSED Figure 2 VENT OPEN Figure 3 VENT EXHAUST OPEN Fresh Air Vent Control On some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent...

Page 7: ...he cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Energy Saving Ideas Do not block air flow i...

Page 8: ...away from coil Outdoor temperature below 60 F 16 C To defrost the coil set selector to FAN position Then set thermostat to warmer position Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position Then set thermostat to a warmer position Dirty air filter ai...

Reviews: