OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Control is OFF. Turn Control ON and set to desired setting.
P1 appears in the display window. Drain water as described in Drainage Section.

Room Temperature lower than the set temperature (Cool Mode). Reset the temperature.

Room Temperature higher than the set temperature (Heat Mode). Reset the temperature.

Shut off  in Heat mode. When the air outlet exceeds 158 °F (70 °C), the automatic heat protection 
engages. Romove any blockages and let appliance cool down.

Air conditioner will not operate.

Air conditioner cooling, but room
is too warm - NO ice forming on 
cooling coil behind decorative
front.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Temperature is set too high. Set temperature to a lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.

Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,
floor and furniture.

Air conditioner turns on and off
rapidly.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils 
more frequently.

Before You Call

Air conditioner cooling, but room 
is too warm - ice forming
on cooling coil behind decorative
front

Outdoor temperature below 60  F (16  C). To defrost the coil, set FAN ONLY mode.

O

O

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY 
mode.

Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, 
set temperature to a higher setting.

Exhaust duct not connected or blocked. See  EXHAUSTING HOT AIR Section.

11

Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 
60°F (16°C).

Air from unit does not feel cold
enough.

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to 
restart when set in the COOL mode.

Reset to a lower temperature.

2009 Electrolux Home Products, Inc.

All rights reserved.

Noise when unit is cooling.

Air movement sound. This is normal. If too loud, set to lower FAN setting.

Vibraion from uneven floor. Move or support appliance correctly on even surface.

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not 
the result of defective workmanship or materials in this appliance.

If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.

Room too cold.

Set temperature too low. lncrease set temperature.

Room Too Hot.

Set temperature too high. Lower setting.

Summary of Contents for 2020252A0373

Page 1: ...2020252A0373 June 2009 Product Registration 3 Unit Description 4 Accessories Included 4 Installation Instructions 5 6 Important Safety Instructions 2 Air Conditioner Features 7 of your Portable Air Conditioner Operating Instructions 8 10 Care and Cleaning 10 Before You Call 11 Major Appliance Warranty 12 Normal Sounds 3 ...

Page 2: ...is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in p...

Page 3: ... Normal Sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of uneven floor Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator d...

Page 4: ...UST AIR OUTLET AIR INTAKE DEHUMIDIFYING DRAIN OUTLET BOTTOM TRAY DRAIN OUTLET EXHAUST HOSE STORAGE WHEN NOT IN USE EXHAUST ADAPTOR A Fig 2 Check all the accessories are included in the package and please refer to the installation instructions for their usage PARTS PARTS NAME QUANTITY Exhaust hose Unit Exhaust Adaptor A Window Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery Fo...

Page 5: ...be placed close to a window or opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a single circuit outlet power source The hose can be extended from its original length of 15 up to 55 but it is the best to keep the length to minimum required Also make sure that ...

Page 6: ...window 4 Close the sliding sash securely against the window slider kit Fig 19 1 Cut the foam seals adhesive type to the proper lengths and attach them to the window frame See Fig 17 2 Attach the window slider kit to the window stool Adjust the length of the window slider kit according to the height of window Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig ...

Page 7: ...TON ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER SLEEP MODE Battery Size AAA Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the ke...

Page 8: ...til the Heat indicator lights 2 Press the Temp buttons for the desired heat setting TIMER OPERATION You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments ...

Page 9: ...e louver stop at desired angle CHECK FILTER FEATURE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light which above the Filter button will illuminate after 250 hours of operation To reset after cleaning the filter press the Filter button and the light will go off FAULT CODE If the display reads EA the room temperature sensor has faile...

Page 10: ...e lower filter B and C by loosening the screws Take down the air inlet grille then remove the air filter as shown in Fig 26 27 Air Filter Cleaning Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean If you plan to st...

Page 11: ... and off rapidly Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set FAN speed to a faster setting to bring air through cooling coils more frequently Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty ...

Page 12: ...pliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER ...

Reviews: