Operating Instructions, CARE & CLEANING

ADDITIONAL THINGS 
YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in 
your control that you should become familiar with. 

Clean your air conditioner occasionally to keep it looking new. 

Be sure to unplug 

the unit before cleaning to prevent shock or fire hazards. 

The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned 
off and on quickly. This prevents overheating of the compressor and possible circuit 
breaker tripping. The fan will continue to run during this time. 
The control will maintain the set temperature within 2 °F, between 62 °F  and 
86 °F (17 °C and 30 °C).

There is a 2-Second delay for the compressor shutting down when selecting 
FAN ONLY/HEAT. This is to cover the possibility of having to roll through to select 
another mode.
After a power outage, the unit will memorize the last setting and return the unit to 
the same setting once power is restored.

CARE & CLEANING

This unit has three filters, they are filter A, B and C. Grasp the upper panel tab and 
take off the filter A which behind the grill of the back panel (Fig.25). Remove the 
lower filter B and C by loosening the screws. Take down the air inlet grille, then 
remove the air filter as shown in Fig.26 

 27.

Air Filter Cleaning

Wash the filter using liquid dishwashing detergent and warm water. Rinse filter 
thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly 
dry before replacing. 

Or, instead of washing you may vacuum the filter clean.

If you plan to store the appliance during the winter, cover it with plastic or return
it to its carton.

Winter Storage

Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet 
and front may be dusted with an oil-free cloth or washed with a cloth dampened 
in a solution of warm water and mild liquid dishwashing detergent. Rinse 
thoroughly and wipe dry.

Cabinet Cleaning

Never use harsh cleaners, wax or polish on the cabinet front.

Be sure to wring excess water from the cloth before wiping around the controls. 
Excess water in or around the controls may cause damage to the air conditioner.

Fig. 25

Filter A

Filter B

Filter C

Fig. 26

Remove two 
screws and
take the air 
intake grille
down

Slide out the filter B 
behind the side panel

Fig. 27

Remove the filter C 
out from the grille

Operating Instructions

The control is capable of displaying temperature in degrees Fahrenheit or degrees 
Celsius. To convert from one to the other and back, press and hold the "TEMP" 
Up (     ) and Down (    ) buttons together for 3 seconds.

Summary of Contents for 2020252A0373

Page 1: ...2020252A0373 June 2009 Product Registration 3 Unit Description 4 Accessories Included 4 Installation Instructions 5 6 Important Safety Instructions 2 Air Conditioner Features 7 of your Portable Air Conditioner Operating Instructions 8 10 Care and Cleaning 10 Before You Call 11 Major Appliance Warranty 12 Normal Sounds 3 ...

Page 2: ...is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in p...

Page 3: ... Normal Sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of uneven floor Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator d...

Page 4: ...UST AIR OUTLET AIR INTAKE DEHUMIDIFYING DRAIN OUTLET BOTTOM TRAY DRAIN OUTLET EXHAUST HOSE STORAGE WHEN NOT IN USE EXHAUST ADAPTOR A Fig 2 Check all the accessories are included in the package and please refer to the installation instructions for their usage PARTS PARTS NAME QUANTITY Exhaust hose Unit Exhaust Adaptor A Window Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery Fo...

Page 5: ...be placed close to a window or opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a single circuit outlet power source The hose can be extended from its original length of 15 up to 55 but it is the best to keep the length to minimum required Also make sure that ...

Page 6: ...window 4 Close the sliding sash securely against the window slider kit Fig 19 1 Cut the foam seals adhesive type to the proper lengths and attach them to the window frame See Fig 17 2 Attach the window slider kit to the window stool Adjust the length of the window slider kit according to the height of window Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig ...

Page 7: ...TON ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER SLEEP MODE Battery Size AAA Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the ke...

Page 8: ...til the Heat indicator lights 2 Press the Temp buttons for the desired heat setting TIMER OPERATION You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments ...

Page 9: ...e louver stop at desired angle CHECK FILTER FEATURE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light which above the Filter button will illuminate after 250 hours of operation To reset after cleaning the filter press the Filter button and the light will go off FAULT CODE If the display reads EA the room temperature sensor has faile...

Page 10: ...e lower filter B and C by loosening the screws Take down the air inlet grille then remove the air filter as shown in Fig 26 27 Air Filter Cleaning Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean If you plan to st...

Page 11: ... and off rapidly Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set FAN speed to a faster setting to bring air through cooling coils more frequently Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty ...

Page 12: ...pliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER ...