The 2
nd
Generation DC Series VRF Indoor Units
Ka
ysun
2
nd
Gener
ation DC Series Duct VRF Indoor Un
its Engineering Da
ta Book
201805 5
KPDHF-560 DN4.0
Table 1.4: KPDHF-560 DN4.0 specifications
Model name
KPDHF-400 DN4.0
KPDHF-450 DN4.0
KPDHF-560 DN4.0
Power supply
1-phase, 220-240V, 50/60Hz
Cooling
1
Capacity
kW
40
45
56
kBut/h
136.5
153.6
191.1
Input
W
1800
1800
2272
Heating
2
Capacity
kW
45
56
63
kBut/h
153.6
191.1
215.0
Input
W
1800
1800
2272
Fan motor
Model
ZKSN-920-8-12-1
Type
DC
Brand
Nidec/Yongan
Speed (H/M/L)
r/min
1060/1015/960/900/840/785/735
1103/1043/978/927/869/820/755
Coil
Number of rows
4
5
Tube pitch × row pitch
mm
21×13.37
21×13.37
21×13.37
Fin spacing
mm
1.5
1.5
1.5
Fin type
Hydrophilic aluminum
Tube OD and type
mm
Ф7 Inner groove
Dimensions (L×H ×W)
mm
1602×588×47
1602×588×47
1602×588×53.84
Number of circuits
28
28
28
Airflow rate
3
m
3
/h
6500/6150/5800/5450/5100/4750/4400
7400/7000/6600/6200/5800/5400/5000
External static pressure
4
Pa
300 (100~400)
Sound pressure level
5
dB(A)
60/59/58/57/55/54/52
59/58/57/56/55/53/51
Sound power level
dB(A)
78/77/76/75/73/72/70
77/76/75/74/73/71/69
Unit
Net dimensions
6
(W×H×D)
mm
2010×905×680
Packed dimensions
(W×H×D)
mm
2095×969×689
Net/Gross weight
kg
210/235
218/248
Refrigerant type
R410A
Throttle
Type
Electronic expansion valve
Model
DPF(TS2)4.5C-02
Design pressure (H/L)
MPa
4.4/2.6
Pipe
connections
Liquid/Gas pipe
mm
Ф15.9/Ф28.6
Drain pipe
mm
OD Ф32
Notes:
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
3. Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model.
4. Stable operation external static pressure range. (Note: setting external static pressure outside the unit’s optimal static pressure range may lead to higher
noise levels and lower airflow rate. For the optimal external static pressure range refer to the unit’s installation manual.)
5. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured 1.4m below the unit in a semi-
anechoic chamber.
6. Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.