6
2010 PERFORMANCE DATA
*
Sleeve / Chassis Dimensions
27" Sleeve
Height (inches)
16 3/4
16 3/4
16 3/4
Width (inches)
27
27
27
Depth (inches)
16 3/4
16 3/4
Friedrich WSC
Sleeve
Fedders A
Sleeve
Fedders B Sleeve*
Sleeve Dimensions
Width
Max. Depth
WSD Sleeve
16 3/4
27
16 3/4
23
7 1/2
9/16
17 1/4
27 1/4
15 5/16
Chassis
15 3/4
26 1/2
21
22
-
-
-
-
-
Depth
with
Front
Minimum
Extension
Into Room
Minimum
Extension
Outside
Height
TTW Finished Hole
Height
Width
Depth
Model
WALLMASTER
Specifications
WallMaster Heat Pump heating information
(
shown in
red)
indicates heat pump heating performance. WallMaster Electric Heat heating information
(shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
Estar
Model
Cooling
Capacity Btu
Heating
Capacity Btu
Volts
Rated
Cooling
Amps
Cooling Watts
Heating
Amps
Heating
Watts
Energy
Efficiecy Ratio
EER
Moisture
Removal
Pints/HR
Room
Side Air
Circulation
CFM
Sleeve
Net Weight
Lbs
WALLMASTER
Cool only
WS08C10
*
7800
NA
115
7.1
788
NA
NA
9.9
1.2
250
WSD
93
WS10C10
*
9700
NA
115
10.0
1032
NA
NA
9.4
2.4
257
WSD
103
WS12C10
*
11900
NA
115
11.8
1266
NA
NA
9.4
3.3
295
WSD
112
WS10C30
*
9500/9200
NA
230/208
4.5/4.7
989/958
NA
NA
9.6/9.6
1.5
300
WSD
101
WS13C30
*
12600/12300
NA
230/208
6.3/6.7
1340/1309
NA
NA
9.4/9.4
3.6
290
WSD
109
WS15C30
*
14500/14500
NA
230/208
8.3/8.2
1706/1706
NA
NA
8.5/8.5
4.2
290
WSD
119
Heat Pumps
WY09C33
*
9300/9000
7300/7300
230/208
4.4/4.7
989/957
3.8/4.0
839/793
9.4/9.4
2.1
250
WSD
103
WY12C33
*
12000/11800
9350/9200
230/208
6.1/6.4
1395/1372
4.8/5.1
1062/1010
8.6/8.6
2.6
275
WSD
111
Cool with Electric Heat
WE10C33
*
9500/9200
11000/9100
230/208
4.5/4.7
989/958
16.0/14.7
3550/2950
9.6/9.6
1.5
300
WSD
121
WE13C33
*
12600/12300
11000/9100
230/208
6.3/6.7
1340/1309
16.0/14.7
3550/2950
9.4/9.4
3.6
290
WSD
107
WE15C33
*
14500/14500
11000/9100
230/208
8.3/8.8
1706/1706
16.0/14.7
3550/2950
8.5/8.5
4.2
290
WSD
116
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature for two
consecutive minutes) and terminated at 43°F (outdoor coil temperature). During
defrost, the compressor stops and the electric heat starts, then operates with
the fan to maintain indoor comfort. The unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
As an
partner, Friedrich Air Conditioning Co. has determined that the selected
(
) meet the
guidelines for ener
gy efficienc
y.
All models use
environmentally
friendly R-410A
refrigerant.
R-410A
WS08C10
*
57
23
55
60
129
167
65
98
11
31
154
462
7.1
32.0
32.5
257
1085
15
WS10C10
*
53
27
53
53
134
177
63
98
10
36
145
500
10.0
40.0
37.0
260
1080
15
WS12C10
*
54
26
52
55
128
169
60
106
11
28
145
500
11.8
57.0
45.0
300
1380
15
WS10C30
*
55
25
55
60
123
165
66
100
14
28
155
440
4.5
18.5
39.0
300
1400
15
WS13C30
*
51
29
51
51
134
179
59
100
8
40
138
535
6.3
26.0
40.0
280
1300
15
WS15C30
*
45
35
45
46
135
181
54
101
9
40
130
545
8.3
41.0
49.0
250
1345
15
WY09C33
*
54
26
54
54
123
164
65
101
12
22
150
450
4.4
3.8
20.0
40.5
251
1335
20
WY12C33
*
51
29
51
51
127
147
58
101
12
26
145
475
6.1
4.8
33.0
265
1330
20
WE10C33
*
56
24
56
56
128
150
58
110
4
24
153
477
4.5
16.0
18.5
39.0
260
1455
20
WE13C33
*
46
34
46
46
128
174
55
99
9
34
135
500
6.3
16.0
26.0
40.0
240
1350
20
WE15C33
*
45
35
45
46
135
181
54
101
9
40
130
545
8.3
16.0
41.0
43.0
250
1345
20
*
Due to continuing research and technology, performance data and 8th character (engineering) are subject to change without notice.
** Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R410A
Dischar
ge
Temp
Suction
Temp
Liquid
Temp
Super
Heat
Evap
CFM
Motor
RPM
Locked
Rotor Amps
Charge in
OZ.
BREAKER
FUSE
60 Hertz
Amps
Sub-
Coolin
g
OPERATING
PRESSURES
ELECTRICAL RATINGS
R410A
Suction
Dischar
ge
Amps
Cool
Amps
Heat
W
A
L
L
M
A
S
T
E
R
EVAPORATOR AIR TEMP.
DEG. F
EVAPORATOR TEMP.
DEG. F
CONDENSER
TEMPERATU
RE DEG. F
Discharge Air
Temp. Drop
F.
T(in)
T(out)
COOLING
PERFORMANCE
DATA**
19 3/4
* Due to continuing research in new energy-saving technology, specifi cations are subject to change without notice.
*
Due to continuing research in new energy-saving technology, performance data and 8th and 9th character are subject to change without notice.
Summary of Contents for WallMaster WE10C33
Page 58: ...NOTES...
Page 59: ...NOTES...