PROPERTY DAMAGE HAZARDS
FIRE DAMAGE HAZARDS:
•
Read the Installation/Operation Manual for this air conditioning unit prior to operating.
•
Use air conditioner on a single dedicated circuit within the specifi ed amperage rating.
•
Connect to a properly grounded outlet only.
•
Do not remove ground prong of plug.
•
Do not cut or modify the power supply cord.
•
Do not use extension cords with the unit.
•
Failure to follow these instructions can result in fi re and minor to serious property damage.
WATER DAMAGE HAZARDS:
•
Improper installation maintenance, or servicing of the air conditioner unit, or not following the above
Safety Warnings
can result in water damage to personal items or property.
•
Insure that the unit has a suffi cient pitch to the outside to allow water to drain from the unit.
•
Do not drill holes in the bottom of the drain pan or the underside of the unit.
•
Failure to follow these instructions can result in result in damage to the unit and/or minor to serious
property damage.
4
INTRODUCTION
This service manual is designed to be used in conjunction with the operation and installation manuals provided
with each unit.
This service manual was written to assist the professional HVAC service technician to quickly and accurately
diagnose and repair any malfunctions of this product.
This manual, therefore, will deal with all subjects in a general nature. (i.e. All text will pertain to all models).
IMPORTANT
: It will be necessary for you to accurately identify the unit you are
servicing, so you can be certain of a proper diagnosis and repair.
(See Unit Identifi cation.)
Condenser/Fan Shroud
Accumulator
Compressor
Condenser Fan Blade
Control Key Pad
Filter
Outdoor Grille
Condenser Air Intake
Condenser
Air Discharge
Air Discharge
Air Intake
Return Air Grille
Decorative Front
Evaporative Coil
Blower Wheel
Sleeve
Blower/Fan Motor
Condenser Coil
Vents
Summary of Contents for WallMaster WE10C33
Page 58: ...NOTES...
Page 59: ...NOTES...