background image

10

SAVE THIS CERTIFICATE.  

It gives you specific rights, you may also have other rights which may vary from state to state and province to

province.

In the event that your unit needs servicing, contact your nearest authorized service center.  If you do not know the nearest service center, ask
the company that installed your unit or contact us - see address and telephone number above.

When requesting service:

 please have the model and serial number from your unit readily available.

Unless specified otherwise herein, 

the following applies:

PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

LIMITED WARRANTY - FIRST YEAR  (Eighteen (18) Months from the original date of purchase or twelve (12) months from
installation).  

Any defect in the unit’s material or workmanship will be repaired or replaced free of charge by our authorized service center

during the normal working hours; and

LIMITED WARRANTY - SECOND THROUGH FIFTH YEAR  (Sixty-six (66) months from the date of purchase) ON THE SEALED REFRIG-
ERATION SYSTEM.  

Any part of the sealed refrigeration system on the P-series that is defective in material or workmanship will be repaired or

replaced free of charge (excluding freight charges) by our authorized service center during normal working hours.  The sealed refrigeration
system consists of the compressor, metering device, evaporator, condenser, reversing valve, check valve, and the interconnecting tubing.

These warranties apply only while the unit remains at the original site and only to units installed inside the continental United
States, Alaska, Hawaii, Puerto Rico and Canada.  The warranty applies only if the unit is installed and operated in accordance
with the printed instructions and in compliance with applicable local installation and building codes and good trade practices.

For international warranty information, contact the Friedrich Air Conditioning Company - International Division.

Reasonable proof must be presented to establish the original purchase date, otherwise the beginning date of this certificate will be considered
to be our shipment date plus sixty days.  Replacement parts can be new or remanufactured.  Replacement parts and labor are only warranted
for any unused portion of the unit’s warranty.

We will not be responsible for and the user will pay for:

1.  Service calls to:
     A) Instruct on unit operation.  B) Replace house fuses or correct house wiring.  C) Clean or replace air filters.  D) Remove
     the unit from inaccessible locations.  E) Correct improper installations.

2.  Parts or labor provided by anyone other than an authorized service center.

3.  Damage caused by:

A) Accident, abuse, negligence, misuse, riot, fire, flood, or acts of God.  B) Operating the unit where there is a corrosive atmo-
sphere containing chlorine, fluorine, or any damaging chemicals (other than in a normal residential environment).  C) Unauthorized
alteration or repair of the unit, which in turn affects its stability or performance.  D) Failing to provide proper maintenance and
service.  E) Using other than a "Seacoast Protected" unit in a coastal environment.  F) Using an incorrect power source.  G) Faulty
installation or application of the unit.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure
of this unit.  We have not made and do not make any representation or warranty of fitness for a particular use or purpose and
there is no implied condition of fitness for a particular use or purpose.  We make no expressed warranties except as stated in
this certificate.  No one is authorized to change this certificate or to create for us any other obligation or liability in connection
with this unit.  Any implied warranties shall last for one year after the original purchase date.  Some states and provinces do
not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions may not apply
to you.  The provisions of this warranty are in addition to and not a modification of or subtraction from the statutory warran-
ties and other rights and remedies provided by law.

In case of any questions regarding the provisions of this warranty, the English version will govern.

FRIEDRICH AIR CONDITIONING CO.

Post Office Box 1540 · San Antonio, Texas 78295-1540

(210) 357-4400 · FAX (210) 357-4480

Friedrich WallMaster

®

 P-Series

Packaged Terminal Air Conditioners

Limited Warranty

Revised 8/01

Summary of Contents for WallMaster PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

Page 1: ...T PROFILE Available in heat pump or electric heat Front cover fastens to chassis with thumbscrews hidden from user Emergency heat compressor override switch on all heat pumps Single totally enclosed c...

Page 2: ...9 26 3 5 1 1 10 230 208 253 198 6 6 0 9 38 6 8 1 10 265 292 239 3 0 0 9 18 3 1 15 265 292 239 3 9 0 9 22 2 3 9 1 12 265 292 239 5 1 0 9 26 3 5 1 1 10 265 292 239 6 6 0 9 38 6 8 1 10 250 60 250 60 325...

Page 3: ...0 54 0 81 0 92 17640 16965 15705 16800 15840 14610 16140 14700 13275 15120 13425 11835 13455 11580 10230 1288 1309 1323 1404 1418 1435 1579 1581 1579 1707 1705 1710 1862 1862 1870 5 5 5 5 5 6 5 9 5 9...

Page 4: ...2 3 20 3 27 8 30 6 30 3400 2780 230 208 11600 9500 3500 2880 15 3 13 9 19 20 6 20 2500 2050 8500 7000 2600 2150 11 4 10 4 14 1 15 6 15 5000 4090 17000 13900 5210 4300 22 3 20 3 27 8 30 6 30 2500 8500...

Page 5: ...l Opening 10 Maximum Insulation 50 Max 13 Main Studs Jack Stud LINTEL Mounting Screw Holes No holes are permitted in the top or bottom of the sleeve Exception PXDR10 Drain Kit Typical Wall Sleeve Inst...

Page 6: ...e be attached to the louver and an anchor point inside the building during installation When using an external drain system the condensate is removed through either of two drain holes on the back of t...

Page 7: ...hall have a built in damper capable of providing at least 60 CFM of fresh air into the conditioned area A fine mesh screen shall filter the incoming fresh air There must be a provision for locking the...

Page 8: ...vy gauge 6063 T5 aluminum alloy Clear extruded aluminum Dark bronze acrylic enamel Also available in custom colors PXDR10 CONDENSATE DRAIN KIT Attaches to the bottom of the wall sleeve for internal dr...

Page 9: ...for wall mounted thermostat control of the unit REPLACEMENT FILTER PACK These are original equipment return air filters They are reusable and can be cleaned by vacuuming washing or blowing out and are...

Page 10: ...ment parts can be new or remanufactured Replacement parts and labor are only warranted for any unused portion of the unit s warranty We will not be responsible for and the user will pay for 1 Service...

Page 11: ...setting Front cover fastens to chassis easily with thumbscrews hidden from user Thermostat limiter switch Emergency heat switch heat pump models Easy access easy to clean filter Made in the U S A UL...

Page 12: ...Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com Printed in the U S A PTACBW02 04 02 Multiplesolutions Onetrustedname Fri...

Reviews: