23
STEP 7.
Cut two pieces of standard 1" lumber (supplied by installer)
to the length and width required. Place in front and back of
bottom sill channel as shown in Figure 31. Secure with nails
(supplied by installer).
STEP 8.
Seal all holes in the sleeve with caulking compound (supplied
by installer).
STEP 9.
Complete the installation by following STEPS 5.3 through 7 of
Standard Window Installation (Page 18). Window seal gasket
mentioned in STEP 6 will not be required.
IMPORTANT:
Before operating your unit, read CIRCUIT PROTECTION
of Standard Window Instructions, under STEP 7..
FRR093
CAULK ALL SIDES
CABINET
ELECTRICAL
RECEPTACLE
MORTAR
NOTE:
ELECTRICAL RECEPTACLE LOCATION
FROM POINT “X” MUST BE WITHIN A MAXIMUM
RADIUS OF 69” FOR 115V UNITS.
POINT “X”
SOLID MASONRY CONSTRUCTION
FRR092
3/4” MINIMUM
SLEEVE FRONT
1” THICK LUMBER
1” MINIMUM
INSIDE WALL
EXTERIOR WALL
MAX. WALL
THICKNESS
ALLOWED 8-1/2”
1 1/4” SCREWS (F IN PARTS LIST) / 3 EA. SIDE
NAILS MAY BE USED IF DESIRED.
3/4” MINIMUM FRONT
EDGE OF SLEEVE TO
INSIDE WALL SURFACE.
FRONT EDGE OF LOUVERS
MUST ALWAYS BE OUTSIDE OF
EXTERIOR WALL SURFACE.
TRIM AROUND THE
SLEEVE WITH A
SUITABLE WOOD
MOULDING AND
FINISH TO SUIT.
CAULK ALL AROUND
SLEEVE ON OUTSIDE
TO INSURE A WEATHER
TIGHT SEAL.
1/4” SLOPE DOWN.
POSITION AND SECURE
SLEEVE DOWNWARD.
SLOPE OUTSIDE FOR
DRAINAGE.
Figure 30
Figure 31