background image

18

WARNING:  – EXPLOSION HAZARD –

SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.

HAZARDGARD

®

ROOM AIR CONDITIONERS 

LIMITED WARRANTY

LIMITED ONE YEAR PARTS WARRANTY 

1. Limited warranty – One year

. Friedrich warrants that it will provide a replacement for any part of this HazardGard Room Air

Conditioner found defective in material or workmanship for a period of one (1) year from the date of original purchase. 

2. Limited warranty – One year.

The Friedrich warranty also covers the cost of labor for repairing any compressor, condenser,

evaporator or inter-connecting tubing found defective within the warranty period, providing the unit is returned to an authorized
Friedrich Repair Station located within the Continental United States. 

The Friedrich warranty does not cover:

(1) Any charges for removal, transportation or reinstallation of the unit; (2) the cost of labor to replace parts other than those
described above; and (3) does not apply to any HazardGard Room Air Conditioner that has been subject to (a) accident, misuse,
flood, fire, or neglect; (b) repairs or alterations outside of the Friedrich Authorized Dealer or Service Center so as to affect adversely
its performance and reliability; or (c) any repairs or servicing as a result of using parts not sold or approved by Friedrich. 

LIMITATIONS: This warranty is a LIMITED warranty. Anything in the warranty notwithstanding, IMPLIED WARRANTIES
FOR PARTICULAR PURPOSE AND MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS
WARRANTY.

MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR

INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

(10-04)

Summary of Contents for SH15

Page 1: ...Installation Operation Manual Hazardous Duty Room Air Conditioner 230 Volt SH15 SH20 www segind com br...

Page 2: ...s manual and on your appliance Always read and obey all safety messages This is a safety Alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messag...

Page 3: ...well 4 When you rst turn on your Friedrich set the thermostat to its coldest position to cool the room When the desired temperature is reached turn the thermostat control to ward the warmer position u...

Page 4: ...outdoor temperatures as low as 45 F 7 C Freezing should only occur whentheoutsideairisdampandbelow45 F 7 C Iftheindoor Maintenance Checklist coilshouldiceoverwhilecooling setthethermostattothewarm est...

Page 5: ...enum chamber for quieter more ef cient cooling Entire unit test run in environmental chamber before crating Eight way air ow control for uniform air circulation Patented electronic control circuit Con...

Page 6: ...hassis Only alternating current A C no direct current D C can be used An overloaded circuit will invariably cause malfunction or failure of the air conditioner therefore it is extremely important that...

Page 7: ...1 HEX HEAD 4 4 T U N D L E W T A L F 4 2 0 1 3 4 SCREW SHEET METAL 12A x 2 7 WINGBOARD ANGLE MOUNTING 5 WINGBOARD ANGLE TOP 1 6 WINGBOARD ANGLE SIDE 2 7 SCREW SHEET METAL 8A x 3 8 2 WINGBOARD MOUNTIN...

Page 8: ...d and two one light colored and one dark colored gaskets from beneath the unit and place them in a safe area away from the unit STEP 3 Remove the chassis retainer by removing the far right screw in th...

Page 9: ...B TAB Detail B 1 Detail B 2 LOOP Position the sill plate into the cabinet with the sill plate holes to the back Align the plate 2 inches from the front of the cabinet and secure it with a nut and bolt...

Page 10: ...inet Carefullyslidethecabinet through the open window until the sill plate channel rests behind the window sill and the top support angle rests against the window See Figure D Center the cabinet side...

Page 11: ...Installation Sill Plate 10 24 SCREW 10 24 FLAT NUT 3 8 10 MM SLOPE DOWN 12A X 2 SHEET METAL SCREW 1 X 2 OR 2 X 4 SPACER BETWEEN WALL AND BRACKET SHOULD BE USED ON ALU MINUM ASBESTOS OR VINYL SIDING F...

Page 12: ...ng steel clips Item 10 to the edges of the cut wingboard panels See Figure G NOTE FOR REASONS OF SECURITY AND SAFETY THE CUSTOMER MUST PROVIDE A MEANS OF PREVENTING THE WINDOW FROM OPENING STEP 8 When...

Page 13: ...ow the suggested typical installations in Figure L M or N on Page 15 NOTE IF THE WALL CONSTRUCTION IS TYPICAL FRAME OR 2 X 4 STUDDING WITH BRICK OR STONE VENEERS LOCATE THE HOLE NEXT TO ONE OF THE STU...

Page 14: ...WEATHER CABINET CAULK ALL SIDES SHIM THE VOID SPACE AT THE TOP AND SIDES WITH WOOD AS REQUIRED CAULK ALL SIDES WEATHER CABINET SHIM VOID SPACES AT TOP AND SIDES WITH WOOD AS REQUIRED FRAME WALL CONST...

Page 15: ...es in each side at the locations shown Figure O and install four 4 12 x 2 screws Item 4 If the hole construction in Step 2 provides a sturdy mount with solid vertical studs no support brackets are req...

Page 16: ...wiring must be provided to this junction box in accordance with NATIONAL ELECTRIC CODE ARTICLE 501 Field and equipment grounds are to be terminated at the post in the junction box with the green scre...

Page 17: ...e grille up and onto the unit s latches at the bottom STEP 3 You have completed your installation Conduct a review of your installation to insure that the unit is safely and securely installed Refer t...

Page 18: ...nental United States The Friedrich warranty does not cover 1 Any charges for removal transportation or reinstallation of the unit 2 the cost of labor to replace parts other than those described above...

Reviews: