background image

12

Figure G

Figure H

Figure I

STEP 6

INSTALL SIDE WINGBOARD PANELS: Be sure that the cabinet has been secured to the window sill and the outside
support brackets have been installed as shown in Figures D and E on Page 11. Raise the window sash and install the right
and left side wingboard panels (See Figure H).

STEP 7

INSTALL WINDOW SEALING GASKETS: Measure and cut the vinyl window seal gasket (grey color, Item #12) to fit
the width of the window and install as shown in Figure I. Pull the window sash down behind the gasket. Measure and cut
the dark foam window seal gasket (Item #13) and install it between the upper glass panel and the top part of the lower sash
(See Figure I).

S

TEP 5

ASSEMBLE CLIPS TO WINGBOARD PANELS: Assemble "J" type speed nuts (Item #9) and spring steel clips (Item
#10) to the edges of the cut wingboard panels (See Figure G).

NOTE: FOR REASONS OF SECURITY AND SAFETY, THE CUSTOMER MUST PROVIDE A MEANS OF PREVENTING

THE WINDOW FROM OPENING.

STEP 8

When possible, caulk the outside of the installation with industrial type caulking to prevent air and water leaks.

"J" TYPE SPEED NUT (ITEM #9)

2 REQUIRED

SPRING STEEL CLIP (ITEM #10)
2  REQUIRED

CUT EDGE

SLIDE CLIP OVER CUT EDGE OF WINGBOARD PANEL

CENTER THE HOLE IN THE SPEED NUT OVER 

THE SLOT IN THE WINGBOARD PANEL

CUT WINGBOARD PANEL

TOP OF CABINET

PLACE WINGBOARD PANEL IN WINDOW JAM TO
COMPRESS THE SPRINGS INSIDE THE RUNNERS, 
AND SWING THE PANEL INTO PLACE INDICATED
BY THE DOTTED LINE.

WINDOW JAM

SECURE THE SIDE WINGBOARD PANELS TO
THE SIDE ANGLES WITH FOUR (4) #8 X 1/2"
LONG SCREWS (ITEM #11), TWO ON EACH SIDE.

SECTION A - A

SECTION B - B

LOWER WINDOW SASH

VINYL WINDOW SEAL GASKET

TOP WINGBOARD ANGLE

VINYL WINDOW SEAL GASKET ITEM #12)

FOAM WINDOW SEAL GASKET (ITEM # 13)

Summary of Contents for SH15

Page 1: ...Installation Operation Manual Hazardous Duty Room Air Conditioner 230 Volt SH15 SH20 www segind com br...

Page 2: ...s manual and on your appliance Always read and obey all safety messages This is a safety Alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messag...

Page 3: ...well 4 When you rst turn on your Friedrich set the thermostat to its coldest position to cool the room When the desired temperature is reached turn the thermostat control to ward the warmer position u...

Page 4: ...outdoor temperatures as low as 45 F 7 C Freezing should only occur whentheoutsideairisdampandbelow45 F 7 C Iftheindoor Maintenance Checklist coilshouldiceoverwhilecooling setthethermostattothewarm est...

Page 5: ...enum chamber for quieter more ef cient cooling Entire unit test run in environmental chamber before crating Eight way air ow control for uniform air circulation Patented electronic control circuit Con...

Page 6: ...hassis Only alternating current A C no direct current D C can be used An overloaded circuit will invariably cause malfunction or failure of the air conditioner therefore it is extremely important that...

Page 7: ...1 HEX HEAD 4 4 T U N D L E W T A L F 4 2 0 1 3 4 SCREW SHEET METAL 12A x 2 7 WINGBOARD ANGLE MOUNTING 5 WINGBOARD ANGLE TOP 1 6 WINGBOARD ANGLE SIDE 2 7 SCREW SHEET METAL 8A x 3 8 2 WINGBOARD MOUNTIN...

Page 8: ...d and two one light colored and one dark colored gaskets from beneath the unit and place them in a safe area away from the unit STEP 3 Remove the chassis retainer by removing the far right screw in th...

Page 9: ...B TAB Detail B 1 Detail B 2 LOOP Position the sill plate into the cabinet with the sill plate holes to the back Align the plate 2 inches from the front of the cabinet and secure it with a nut and bolt...

Page 10: ...inet Carefullyslidethecabinet through the open window until the sill plate channel rests behind the window sill and the top support angle rests against the window See Figure D Center the cabinet side...

Page 11: ...Installation Sill Plate 10 24 SCREW 10 24 FLAT NUT 3 8 10 MM SLOPE DOWN 12A X 2 SHEET METAL SCREW 1 X 2 OR 2 X 4 SPACER BETWEEN WALL AND BRACKET SHOULD BE USED ON ALU MINUM ASBESTOS OR VINYL SIDING F...

Page 12: ...ng steel clips Item 10 to the edges of the cut wingboard panels See Figure G NOTE FOR REASONS OF SECURITY AND SAFETY THE CUSTOMER MUST PROVIDE A MEANS OF PREVENTING THE WINDOW FROM OPENING STEP 8 When...

Page 13: ...ow the suggested typical installations in Figure L M or N on Page 15 NOTE IF THE WALL CONSTRUCTION IS TYPICAL FRAME OR 2 X 4 STUDDING WITH BRICK OR STONE VENEERS LOCATE THE HOLE NEXT TO ONE OF THE STU...

Page 14: ...WEATHER CABINET CAULK ALL SIDES SHIM THE VOID SPACE AT THE TOP AND SIDES WITH WOOD AS REQUIRED CAULK ALL SIDES WEATHER CABINET SHIM VOID SPACES AT TOP AND SIDES WITH WOOD AS REQUIRED FRAME WALL CONST...

Page 15: ...es in each side at the locations shown Figure O and install four 4 12 x 2 screws Item 4 If the hole construction in Step 2 provides a sturdy mount with solid vertical studs no support brackets are req...

Page 16: ...wiring must be provided to this junction box in accordance with NATIONAL ELECTRIC CODE ARTICLE 501 Field and equipment grounds are to be terminated at the post in the junction box with the green scre...

Page 17: ...e grille up and onto the unit s latches at the bottom STEP 3 You have completed your installation Conduct a review of your installation to insure that the unit is safely and securely installed Refer t...

Page 18: ...nental United States The Friedrich warranty does not cover 1 Any charges for removal transportation or reinstallation of the unit 2 the cost of labor to replace parts other than those described above...

Reviews: