3. Piping Diagrams
Heating
Heat exchanger
Gas pipe connection port
(flare connection)
Cooling
M
Th3
Th1
Sirocco Fan
Th2
Liquid pipe connection port
(flare connection)
LOC.
Description
PCB Connector
Th1
Thermistor for suction air temperature
CN_ROOM
Th2
Thermistor for evaporator inlet temperature
CN_PIPE/IN
Th3
Thermistor for evaporator outlet temperature
CN_PIPE/OUT
- 4 -