INSTALLING THE
INTERFACE MODULE AND
SMOKE ALARM
The Interface Module is mounted
inside the Smoke Alarm mounting
base.
1) Using the base as a template,
mark the position of the two
fixing holes on the ceiling.
2) Drill two 5mm holes and fit the
wall plugs.
3) Fix the base to the ceiling with
the screws supplied. Do not over-
tighten the fixing screws.
4) Fit the Interface Module to its
rear cover and snap together.
Ensure that the connection
cable is correctly located in the
cable entry recess and is not
trapped between the front and
rear cover.
5) Fix the Interface Module into
t h e m o u n t i n g b a s e i n t h e
position shown below using the
adhesive pads supplied.
Important:
Ensure that the
release slot is not positioned
against the side wall of the
base.
Wirefree Alarm Interface Module