Fridge Electric ArticPro User Manual Download Page 6

6

15

CONTROL PANEL

ATTENTION:

 

If the unit is turned off in cool or Dehumidify mode and restarted immediately, then the air 

conditioner will wait at least 3 minutes before running again.

Buttons

1. 

Timer:

 

Press to set timer. Use the up and down arrows to set time. see Page 11 for more info.

Swing:

 

Press to make the vertical vent swing automatically. Press again to stop.

Speed:

 

Press for 2 seconds to select high, medium or low fan speed.

Up/down:

 

Press the up or down button to set the temperature. In Timer Mode, this adjusts the 

time. Press both buttons at the same time to switch between celsius and Fahrenheit.

mode:

 

Press this button to select cool, dehumidify or fan mode. 

Economy mode:

 

Press for the energy saving mode (cool mode only).  The   in the leD 

display will blink indicating the economy mode is selected. The temperature will automatically switch to 
81˚F and a low fan speed. These settings can not be changed. To cancel, press this button again.

 

Power:

 

Press this button to turn the unit on/off.

LED display

2. 

 

Timer 

 

 

 

 

      Dehumidify, Cool, and Fan Modes

Water Injection indicator 

 

 

      Water Full indicator 

 

Remote Control sensor  

 

 

      High, Medium and Low fan speeds

Indicates time and temperature. 

also displays error codes. 

In case of malfunction, refer to the Troubleshooting Guide in this manual.

Indicates Celsius or Fahrenheit degrees.

C F

Mode

mAINTENANCE

Cleaning

ATTENTION:

 

Turn off the unit and pull the plug out before any cleaning.

Energy Tip!

 

Dust in the air filter will reduce efficiency. Clean the filter every 

2-4 weeks for better performance.

Cleaning the surface 
Clean the surface of the unit with a duster or a damp soft cloth. Do not use a 
chemical solvent like benzene, alcohol, gasoline, etc. as it may damage or even 
deform the unit.

Cleaning the air filter

Pull out the air filters (2).

1. 

Wash the air filters by immersing them gently into 

2. 

warm water (under 104°F or 40°C) with a mild soap. 
Use a soft, lint-free cloth. 
Rinse the filters thoroughly and let them dry 

3. 

completely in an area out of direct sunlight. 
Push the air filters back into their original positions.

4. 

End of season

Switch off the unit and disconnect the plug from the power supply.

1. 

Pull the plug from the drain mouth and remove the water from the basin. You 

2. 

can remove the water entirely by carefully tilting the unit back. 
Clean the air filters. Let them dry completely before inserting them back in the 

3. 

ArcticPro. 
Run the unit in Fan Mode on the low setting for half a day to dry the inside and 

4. 

prevent mildew.
Wrap the cord around the cord storage on the back of the unit.

5. 

Remove the air exhaust duct and store it in a dry and safe place.

6. 

Wrap the unit with a plastic bag and keep, with all accessories, in a dry place.

7. 

Take the batteries out of the remote control before storage.

8. 

Summary of Contents for ArticPro

Page 1: ...USER MANUAL PORTABLE AIR CONDITIONER 2011 FE A4320A BR14081R 1...

Page 2: ...ows closed during the sunniest part of the day Keep the filters clean Under normal conditions the filters should be cleaned about every 30 days More frequent cleaning may be necessary depending on the...

Page 3: ...it from the wall outlet Never pull by cord Do not turn the ArcticPro on or off by plugging or unplugging the power cord directly 18 1 2 3 4 5 6 7 8 9 Warranty A This 1 year limited warranty applies t...

Page 4: ...y to cool air for a long period of time When transporting or storing this unit and the cord keep in a dry place free from excessive vibrations and store so as to avoid damage Before storing the produc...

Page 5: ...in the cord have been exposed There is an unusual odor or smoke coming from the unit TROUBLE SHOOTING CONTINUED on page 17 The unit does not operate at all Issue Try Make sure it is plugged in and the...

Page 6: ...ndicates Celsius or Fahrenheit degrees C F Mode MAINTENANCE Cleaning ATTENTION Turn off the unit and pull the plug out before any cleaning Energy Tip Dust in the air filter will reduce efficiency Clea...

Page 7: ...ooling efficiency and decrease noise but also save energy In Cool and Dehumidifying Modes water from the evaporator flows into an inside basin When the water reaches above a set level the pump will ru...

Page 8: ...is no damage to the cord then press the RESET Button If the LCDI Plug trips again then immediately unplug the power supply cord and contact a professional technician or service center WARNING Do not...

Page 9: ...y switch to 81 F and a low fan speed These settings can not be changed To cancel this mode press the Economy Mode button again OPERATION CONTINUED on page 13 9 12 INSTALLATION ATTENTION This length ha...

Page 10: ...the unit off While the unit is off press the Timer button Follow steps 2 3 as indicated 2 above under Sleep Setting Once the chosen amount of time ends the unit will turn on automatically Adjust Cance...