AD Corinte W - ADCS
19
GB
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The guarantee is only valid if the units
are used in the manner intended by the
manufacturer and in accordance with the
Frico mounting and operating instructions.
Application
The AD Corinte W - ADCS air curtain is
supplied with a water coil and is intended
for permanent installation above or beside
entrance doors and other openings up to
3,5 metres in height. Protection class: IP20.
Operation
Air is drawn in at the top/rear of the unit and
blown out downwards/outwards so that it
shields the door opening and minimizes heat
loss. To achieve the optimum curtain effect
the unit must extend the full height/width of
the door opening.
The grille for directing exhaust air is
adjustable and is normally angled outwards to
achieve the best protection against incoming
cold air.
The efficiency of the air curtain depends
on the air temperature, pressure differences
across the doorway and any wind pressure.
NOTE! Negative pressure in the building
considerably reduces the efficiency of the air
curtain. The ventilation should therefore be
balanced.
Vertical mounting
The unit is mounted vertically on the floor
with the exhaust opening facing outwards.
Before installation, decide whether any
electrical connections or water connections
are to be made from below.
Leave the protective plastic in place during
installation. Take care to avoid damaging the
surfaces. For installation see Figure 4.
1. Remove the two screws that secure the
intake grille (A) and remove this.
2. Undo the screws holding the front panel (C)
on the exhuast side (B).
3. Undo the two screws in the front panel and
remove it.
4. Place the edging in level on the floor and
secure it through the countersunk holes
(see Fig. 7). Place the air curtain on the
edging.
5. A flat bar is included for securing the air
curtain. Fixate the air curtain through the
square-shaped hole. Make sure that the flat
bar is not bent when fixing.
6. Secure the top with an angle bracket or
similar to prevent the air curtain from
toppling over. There is a hole in the centre
of the top of the air curtain with an internal
M8 thread for securing the bracket.
7. Hook the front panel (C) onto the edge on
the intake side (A), close and press it into
the slot on the exhaust side (B).
8. Fasten the two screws in the front panel.
9. Secure the front panel on the exhaust side.
10. Replace the intake grille. (A)
To remove dirt and finger prints, polish the
panels with a suitable cleanser. Any print
that may be on the panels is removed with a
suitable solvent.
Horizontal mounting
The unit is mounted horizontally with the
outlet facing downwards. Do not remove
the protecting plastic until mounting is
completed. Be careful so the surfaces are not
damaged.
Mounting less than 180 mm from the ceiling
is not recommended since it will reduce the
flow through the unit.
Two brackets are delivered with the unit
for mounting on the wall or hanging from the
ceiling.
Horizontal mounting on the wall
1. Mount the brackets on the wall according to
measures in Fig. 6a and 6b.
2. Put the unit in place and lock it with an
hexagon key and the included M8 screws.
Mounting and operating instructions
Summary of Contents for Thermozone AD Corinte W ADCS17WH
Page 1: ...AD Corinte W ADCS 16 SE 46 IT 28 RU 22 NO 25 FR 34 NL 37 ES 43 FI 19 GB 40 PL 31 DE 49 DK ...
Page 3: ...AD Corinte W ADCS 3 1 2 80 60 1 2 60 80 3 Ø22 Cu PH2 1 4 Fig 2 Fig 3 Ø22 Cu 2200 2450 500 350 ...
Page 4: ...AD Corinte W ADCS 4 1 2 3 4 5 6 7 8 9 10 A B C Fig 4 ...
Page 5: ...AD Corinte W ADCS 5 Fig 5 ...
Page 7: ...AD Corinte W ADCS 7 Fig 6c Fig 6d 360 243 Ø22 Ø10 15 5 10 Fig 7 80 35 ø12 180 35 25 40 ...