Page 10
9124654 Service Manual Ultra Sonic Humidifier 30001322 2021
3. Operation
WORKING AND ADJUSTMENT ULTRASONIC HUMIDIFIER
If you switch on the humidifier the UV lamp turns on and the water tank
automatically fills up to the first level with filtered water.
Now the oscillator starts to vibrate and the water molecules are blown out of
the unit, by means of the blower, as a very fine mist and this mist is spread
over the products.
The water tanks is filled up to the second level and then stops.
Now the water level drops to the first level and is filled up again, and so on.
Points of attention:
-
Inside the UV lamp there is a measuring cell.
If UV lamp is worn out the red indication lamp on the transformer is lit.
-
UV lamp and oscillator have to be replaced every year.
-
Outside on the water tank a clixon is placed as a safety. Set on 55°C.
-
Clean the air filter under the water tap.
-
Check the position of the adjusting plate slide on top of the humidifier.
• length of unit 750 - 2000 mm: first marking. (Close side)
• Length of unit 2500 mm: first m 2 mm.
• Length of unit 2750 mm: first m 3 mm.
• Lenght of unit 3000 mm: first m 4