Page 8
9124654 Service Manual Ultra Sonic Humidifier 30001322 2021
2. Installation
2.1 Water Supply
●
Use 1/2 inch pipe for water supply. Install a water supply valve and
a strainer (80 mesh or finer) near the humidifier unit to remove
impurities in water.
●
Connect to the main unit the black pressure-tight tube and half union
that are supplied along with the unit.
Before connecting, be sure to flush out any oil and dirt that may be
inside the pipe work with running water.
●
Insert the vinyl hose into the overflow port to connect with the drain pipe.
●
Leave the black cap on the drain port as is. (It is to be used for draining
at the time of repair or inspection.)
CAUTION:
Install a water shock absorbing device in the water supply line
where water hammering is likely to occur.