9
Humidity c timer with momentary switch,
wiring diagram 4
The fan is connected using constant phase (L) and
neutral (N) for automatic humidity control.
Switched live (SL) is connected to activate the fan’s
timer, with a momentary switch. With this setup,
the fan starts immediately. The delay before the fan
stops is 5, 15 or 30 minutes (post-running time),
depending on your preferred control panel setting.
For wiring diagrams for 1-4, see page 7.
Use an ordinary round file to create a suitably
placed smooth cutout in the front cover. Do NOT
use pliers or similar tools, as these may cause the
cover to crack.
NOTE!