7
3. Wiring
Installation work should be performed by a qualified
electrician.
• The fan is double insulated and must not
be earthed
• Push the safety switch up to position 0,
the Off position.
• The cable can be installed either along the surface
using inlets A in the chassis or concealed using
inlets B in the chassis. Both options are shown
below. Use the supplied insulating sleeve for
the cable (FK).
• If you use any of the B inlets, remove the concealed
round plastic cover by tapping inside the break-off
notch from the inside out to the back with a
screwdriver, for example.
Wiring diagrams
EN
A
A
A
A
B
B
B
B
Kabelingångar
A=utanpåliggande
B=dold
on
off
1
2
3
4
SL N L
SL N L
SL N L
SL N L
L
N
L
N
L
N
L
N
Cable inputs
A = surface-mounted
B = concealed