28
The fan runs nonstop
Red LED is constantly lit
(If the fan has been running nonstop for at least 24
hours)
Check operation by opening the bathroom door and
leaving it open for at least half an hour to equalise
humidity levels.
Remove the cover and disconnect the power supply
to the fan by moving the safety switch to 0. Then
return the switch to I.
Green LED is constantly lit
Check that the fan has not been set up for
continuous operation.
(To be done by electricians only.)
If the fan is connected to an external switch for timer
control, switch this off and wait at least 30 minutes.
Remove the cover and disconnect the power supply
to the fan by moving the safety switch to 0. Then
return the switch to I.
No LEDs lit
Remove the cover and disconnect the power supply
to the fan by moving the safety switch to 0. Then
return the switch to I.
If the fan still runs nonstop, you can return the fan as
long as it is within the guarantee period and you have a
receipt. See Guarantee on page 24.
TROUBLESHOOTING GUIDE »