INSTRUCTIONS FOR THE INSTALLER
(*) Necessary size for the installation with cover.
Any possible wall unit over the cook-top must be placed at a
distance of at least 760 mm from the top.
It is advisable to isolate the appliance from the piece of furniture below with a separator, leaving a depression space
of at least 10 mm (fi g. 4).
If the hob is going to be installed on the top of an oven, precautions must be taken to guarantee an installation in
accordance with current accident prevention standards. Pay particular attention to the position of the electric cable
and gas pipe: they must not touch any hot parts of the oven.
Moreover, if the hob is going to be installed on the top of a built in oven without forced cooling ventilation, proper
air vents must be installed to guarantee an adequate ventilation, with the lower air entering with a cross section of at
least 200cm
2
, and the higher air exiting with a cross section of at least 60cm
2
.
•
FASTENING THE TOP
Every cook-top is equipped with a special washer. A set of hooks is also supplied for mounting the cook-top.
Depending on the type of mounting surface, the suitable type of mounting hook is supplied (hook A or hook B).
For the installation proceed as follows:
•
Remove the racks and burners from the top.
•
Turn the appliance upside down and lay the washer S along the external border (fi g. 5).
•
Introduce and place the cook-top in the hole made in the piece of furniture, then block it with the V screws
of the fastening hooks G (fi g.6 / 6A).
• INSTALLATION
ROOM
This appliance is not provided with a device for exhausting the products of combustion.
Regarding room ventilation rules where appliance is installed make reference to the legislation, in conformity with
the local regulations.
•
FOR THE U.K. ONLY
The room containing this hotplate should have an air supply in accordance with BS 5440: Part 2: 1989.
•
All rooms require an openable window, or equivalent and some rooms will require a permanent vent a
well.
•
For room volumes up to 5m
3
an air vent of 100cm
2
is required.
•
For room volumes between 5m
3
and 10m
3
an air vent of 50cm
2
is required.
•
If the room is greater than 5m
3
and has a door that opens directly to the outside, then no air vent is required.
If there are other fuel burning appliances in the same room BS 5440: Part 2:1989 should be consulted to determine
the air vent requirements.
• GAS
CONNECTION
Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). Follow the
instructions indicated in the chapter “gas transformations and adjustments” for the possible adaptation to diff erent
gases.
The appliance must be connected to the gas system by means of stiff metal pipes or fl exible steel pipes having
continuous walls, in compliance with the regulations in force.
Some models are equipped with both cylindrical A and conical B connectors for gas supply (fi g. 7). Please select the
type which is correct for the supply concerned.
The connection must not stress the gas ramp.
Once the installation is over, check the connection seal with a soapy solution.
MODEL
L (mm)
P (mm)
600 - 750
560
480 - 490 (*)
INSTRUCTIONS FOR THE INSTALLER
Summary of Contents for HA640
Page 15: ...RU 15 Freggia 10 24...
Page 16: ...16 3 EEC 2009 142 CE EEC 2004 108 CE 2006 95 CE 89 109...
Page 18: ...18 1 1 6 2 1 1 1 o 1000 10 14 cm 1750 16 18 cm 3000 20 22 cm 3800 24 26 cm...
Page 19: ...RU 19 75 Y 3 50 760 10 4 600 750 560 480 490...
Page 20: ...20 200 2 60 2 S 5 V G 6 6 20 3 200 2 7 3...
Page 22: ...22...
Page 23: ...23 U 3 EEC 2009 142 CE EEC 2004 108 CE 2006 95 CE 89 109...
Page 25: ...U 25 1 1 6 2 1 1 1 1000 10 14 cm C 1750 16 18 cm 3000 20 22 cm 3800 24 26 cm...
Page 26: ...26 75 Y 3 50...
Page 27: ...U 27 760 10 4 200 2 60 2 S 5 V G 6 6 20 3 200 2 2 7 3 600 750 560 480 490...
Page 29: ...U 29...
Page 37: ...PL 37...
Page 38: ...38 598 560 5 0 8 4 8 0 55 95 598 560 5 0 8 4 8 0 55 95...
Page 39: ...598 560 5 0 8 4 8 0 55 95 598 560 5 0 8 4 8 0 55 95...