The third-party device manuals must be referenced for all details regarding connecting the
CAN interface.
Most brands use 500kbps. If 250kbps is required it is available on the Lite with a specific
profile loaded, which must be requested when ordering the Lite or can be loaded during
commissioning by your distributor for Freedom Won technical support.
If you did not purchase a CAN Bus cable to suit your inverter you can make your own
according to Table 4.2. Fig 4.1 provides the standard colour coding for an Ethernet cable
(note that there are other variations so double check this).
Fig 4.1 Pin Configuration for standard RJ45 plug
Table 4.2 Pin Configuration for CAN Bus Control Cable for various supported inverters
Wire
Function
Standard
Lite and
Victron
SMA
Ingeteam
Imeon
Solax
Goodwe
Sofar
CAN
Low
Pin 8
(brown)
Pin 5 (blue/
white)
Labelled
on inverter
Pin 2
(orange)
Pin 1
(orange/
white)
Pin 5
(blue/
white)
Pin 2
(orange)
CAN
High
Pin 7
(brown/
white)
Pin 4 (blue)
Pin 1
(orange/
white)
Pin 2
(orange)
Pin 4
(blue)
Pin 1
(orange/
white)
.
Bridge Pin 3 and
Pin 6 on Inverter
end or cable with
a 120Ω resistor
If your inverter is not included in this table, please contact Freedom Won for assistance.