OPERATION (contd.)

Operating the Timer

If you wish to check the timer setting after the timer has been programmed, press the
"TIMER-SET" button on control panel while timer "ON" or "OFF" light is on. The display
will show the hours remaining until the timer function is operating. Pressing "TIMER-
SET" again will increase timer setting.

To Turn Unit On with Timer

1.

While the unit is off, press “TIMER-SET” button on control
panel to program the air conditioning unit to turn on in 1-24
hours. The timer "ON" light will turn on. You may also set
Mode and Thermo Control settings at this time. The unit will
turn on at the programmed time.

If you wish to check the timer, press the "TIMER-SET" button
on control panel while timer "ON" light is on. The display will show the hours remain-
ing until the timer function is operating. Pressing "TIMER-SET" again will increase
timer setting.

2.

To cancel timer setting, press "TIMER-RESET" button. If the power on/off "I/O" but-
ton is pressed while a timer "ON"setting is scheduled, the timer function will be can-
celled and the unit will continue to operate as normal.

To Turn Unit Off with Timer

1.

While the unit is on, press “TIMER-SET” button on control
panel to program the air conditioning unit to turn off in 1-24
hours. The timer "OFF" light will turn on. The unit will turn off
at the programmed time.

2.

To cancel timer setting, press "TIMER-RESET" button. If the power on/off "I/O" but-
ton is pressed while a timer "OFF" setting is scheduled, the unit will turn off and the
programmed "OFF" time will be cleared.

Wireless Remote Control Operation

The Wireless Remote Control has the same
control buttons as are on the Control Panel. All
functions operate the same as described under
"CONTROL PANEL." The remote requires two
"AAA" size batteries (included).

NOTE: The Wireless Remote Control will oper-
ate up to 16 feet (5 meters) from indoor unit.

1.

Press "POWER on/off" button to remotely
operate unit.

2.

Press function buttons, as desired,
to control air conditioner. See
"CONTROL PANEL" for button
controls and functions.

Summary of Contents for RCS-S3000T

Page 1: ...ace both units in their upright positions for a minimum of two hours before operating For best results and more enjoyment from your new FREECOM portable air conditioning unit please read this instruct...

Page 2: ...the unit This time period permits the liquids gases and oils contained within the sealed systems to return to their proper positions OWNER S RECORD Enter product information here for future use Date o...

Page 3: ...esh air conditioned dehumidified air Automatic oscillating louvers provides air distribution over a wide area Low noise rotary compressor cools from air to air no water required Attractive design and...

Page 4: ...l exposition directe du soleil en fermant rideaux et stores etc pour am liorer le rafra chissement Ne pas placer l appareil pr s de rideaux qui risquent de bloquer l entr e ou la sortie d air distanc...

Page 5: ...ter or moisture DO NOT use indoor unit outdoors CAUTION Failure to follow the safety information below can result in minor personal injury property damage damage to the unit and voiding your warranty...

Page 6: ...Air Louver E Air Outlet F Built in Handle G Air Filter H Emergency Water Drain Tube I Water Drain Plug J Power Cord K Flex Tube L Caster Wheels M Connector Cover N Fan O Drain Port outdoor unit P Supp...

Page 7: ...e of approximately 77 F when the unit is initially plugged in and started Press right button to lower cooling setting press left button to raise cooling setting Each press of either button adjusts the...

Page 8: ...ible water leakage 2 Place indoor unit at least 30 from any draperies or other obstructions Carefully push the unit on its castor wheels to desired location 3 Determine a location for outdoor unit If...

Page 9: ...e tube set See Disconnecting Tube Set for detailed information There are two choices for installing the outdoor unit surface placement and wall mounting See below for surface placing the outdoor unit...

Page 10: ...rt belt to wall with the appropriate hardware Disconnecting Tube Set This air conditioner is equipped with convenient quick Connect Couplings which allow for the removal and routing of the Tube Set th...

Page 11: ...h a special safety time delay feature The compressor cooling mechanism may be delayed for up to five minutes This safety feature prevents damage to the compressor The COMP ON light will turn on while...

Page 12: ...button If the power on off I O but ton is pressed while a timer ON setting is scheduled the timer function will be can celled and the unit will continue to operate as normal To Turn Unit Off with Tim...

Page 13: ...or unit NOTE If emptying water tank before DRAIN WATER alert press Power On Off I O button to stop unit if it is operating 1 Unplug power cord from outlet Allow unit to remain off for 3 5 minutes 2 Re...

Page 14: ...m dirty side of filter Turn filter over and vacuum other side Use care not to damage or puncture the filter mesh DO NOT use brushes brooms or other course materials to clean the filters 4 Hold air fil...

Page 15: ...hment STORAGE INDOOR UNIT 1 Press power on off I O button if unit is operating Unplug power cord from outlet 2 Drain water tube See Draining Water Tank on page 13 for detailed instructions 3 For long...

Page 16: ...Check MODE and or THERMO CONTROL selection and adjust for higher air output See OPERATION 4 Allow unit to stand upright for a minimum of two hours before attempting to operate 1 Power voltage is too l...