background image

OPERATION

CAUTION: To avoid damage and voiding your warranty, place both units in their

upright positions for a minimum of two hours before operating. DO NOT operate
unit without air filter properly in place or while tube set is disconnected.

Cooling

This unit is intended to cool a 300-600 square foot area. The unit’s cooling capacity will
vary according to room temperature and humidity. Consult your Freecom dealer for
specific application and suitability.

1.

Plug power cord into a standard household outlet. Use this
product only with the proper electrical voltage. See

“SPECIFICATIONS” on page 3.

WARNING: Do not plug this appliance into an outlet that is being used by other

appliances or electrical devices. When installing the electrical plug into the outlet,
never touch or bend the metal prongs and always push plug into outlet by using the
molded plug. Never use the electrical plug to start or stop the unit and avoid pulling,
folding, or stretching the electrical cord.

2.

Press Power On/Off ("I/O") button on control panel. The unit will power up
and air will begin blowing from the front louvers.

NOTE: This unit is equipped with a special safety time delay feature.
The compressor (cooling mechanism) may be delayed for up to five
minutes. This safety feature prevents damage to the compressor.
The "COMP. ON" light will turn on while the compressor is running.

3.

Press “MODE” button on control panel to choose "AUTO," "HI," "MED,"
"LO," or "FAN." The FAN setting is for air circulation only and does not
provide any cooling. To change from a cooling mode to fan mode, press
power on/off "I/O" button to turn unit off. Press power on/off "I/O" button
again and immediately press "MODE" button to FAN setting. If the air con-
ditioner is re-started, the unit will be in the previously selected mode.

4.

Press either "THERMO CONTROL" button to control a
colder or cooler setting. The default temperature is 77ÞF.
Press right button to lower cooling setting; press left button
to raise cooling setting. Each press of the button will adjust
the temperature approximately 1ÞF. The temperature set-
ting can be adjusted from 68ÞF to 86ÞF.

CAUTION: To avoid injury or damage and voiding the warranty,

DO NOT manually adjust the louvers.

5.

Press “AUTO SWING” button on control panel to begin oscillating
horizontal louvers. The louvers will move slowly up and down for optimum
air distribution. Press button again to maintain a desired “fixed” position to
distribute more cooling air to one side of the room.

11

Summary of Contents for RCS-S3000T

Page 1: ...ace both units in their upright positions for a minimum of two hours before operating For best results and more enjoyment from your new FREECOM portable air conditioning unit please read this instruct...

Page 2: ...the unit This time period permits the liquids gases and oils contained within the sealed systems to return to their proper positions OWNER S RECORD Enter product information here for future use Date o...

Page 3: ...esh air conditioned dehumidified air Automatic oscillating louvers provides air distribution over a wide area Low noise rotary compressor cools from air to air no water required Attractive design and...

Page 4: ...l exposition directe du soleil en fermant rideaux et stores etc pour am liorer le rafra chissement Ne pas placer l appareil pr s de rideaux qui risquent de bloquer l entr e ou la sortie d air distanc...

Page 5: ...ter or moisture DO NOT use indoor unit outdoors CAUTION Failure to follow the safety information below can result in minor personal injury property damage damage to the unit and voiding your warranty...

Page 6: ...Air Louver E Air Outlet F Built in Handle G Air Filter H Emergency Water Drain Tube I Water Drain Plug J Power Cord K Flex Tube L Caster Wheels M Connector Cover N Fan O Drain Port outdoor unit P Supp...

Page 7: ...e of approximately 77 F when the unit is initially plugged in and started Press right button to lower cooling setting press left button to raise cooling setting Each press of either button adjusts the...

Page 8: ...ible water leakage 2 Place indoor unit at least 30 from any draperies or other obstructions Carefully push the unit on its castor wheels to desired location 3 Determine a location for outdoor unit If...

Page 9: ...e tube set See Disconnecting Tube Set for detailed information There are two choices for installing the outdoor unit surface placement and wall mounting See below for surface placing the outdoor unit...

Page 10: ...rt belt to wall with the appropriate hardware Disconnecting Tube Set This air conditioner is equipped with convenient quick Connect Couplings which allow for the removal and routing of the Tube Set th...

Page 11: ...h a special safety time delay feature The compressor cooling mechanism may be delayed for up to five minutes This safety feature prevents damage to the compressor The COMP ON light will turn on while...

Page 12: ...button If the power on off I O but ton is pressed while a timer ON setting is scheduled the timer function will be can celled and the unit will continue to operate as normal To Turn Unit Off with Tim...

Page 13: ...or unit NOTE If emptying water tank before DRAIN WATER alert press Power On Off I O button to stop unit if it is operating 1 Unplug power cord from outlet Allow unit to remain off for 3 5 minutes 2 Re...

Page 14: ...m dirty side of filter Turn filter over and vacuum other side Use care not to damage or puncture the filter mesh DO NOT use brushes brooms or other course materials to clean the filters 4 Hold air fil...

Page 15: ...hment STORAGE INDOOR UNIT 1 Press power on off I O button if unit is operating Unplug power cord from outlet 2 Drain water tube See Draining Water Tank on page 13 for detailed instructions 3 For long...

Page 16: ...Check MODE and or THERMO CONTROL selection and adjust for higher air output See OPERATION 4 Allow unit to stand upright for a minimum of two hours before attempting to operate 1 Power voltage is too l...

Reviews: