background image

FDA700 Rev160509

14

Note:

 Refer to Star or 

Delta windings diagrams 

for generator connections.

Secondary AC Output 

12/24 VAC

To FROG

Primary AC Input

120/240 VAC

From Generator

Voltage Transformer Cable

(Refer to Figure 7)

Figure 8.  Voltage Transformer Wiring

Voltage Transformers

Black Wires

Blue Wires

Green Wire

Blue Wire

(Phase A)

Black Wires

Blue Wires

Orange Wire

White Wire

(Phase B)

Black Wires

Blue Wires

Purple Wire

Tan Wire

(Phase C)

Summary of Contents for FDA700 for Delta Winding

Page 1: ...R THREE PHASE GENERATOR DISPLAY MODELS FDA700 for Delta Winding FDA710 for Star Winding Document Number XE FDA7PM R0A FIRE RESEARCH CORPORATION www fireresearch com 26 Southern Blvd Nesconset NY 11767 TEL 631 724 8888 FAX 631 360 9727 TOLL FREE 1 800 645 0074 ...

Page 2: ...onnectors and Cables 12 Voltage Transformers 14 Current Sensors 15 Star Winding Connections 16 Delta Winding Connections 17 List of Figures Table Figure 1 Controls and Indicators 5 Figure 2 Display Module Mounting Dimensions 7 Figure 3 Signal Interface Module Mounting Dimensions 7 Figure 4 Current Sensor 9 Figure 5 Voltage Transformer 9 Table 1 Line Displays 11 Figure 6 Display Module Wiring 12 Fi...

Page 3: ...current sensors and voltage transformers so that cable runs are short Current and voltage information is passed to the display module over a two wire datalink Built in safety features include voltage fluctuation current overload and high temperature warnings Features Generator Hourmeter Audible Alarm Buzzer Optional Temperature Sensor Optional Specifications Display Module Dimensions 4 1 4 Wide by...

Page 4: ...Clearance for the cables is required This module is mounted close to the current sensors and voltage transformers so the cable runs are short Current and voltage information is passed to the display module over a two wire datalink Current Sensor The current sensors are used to measure current flow through a wire by electromagnetic induction Each phase wire to the main circuit breaker is run throug...

Page 5: ...AGE Display Shows the generator output in volts of the selected line AMPS CURRENT Display Shows the current in amperes of the selected line MODE Button Press to show total generator hours and sensor temperature LINE Button Selects the line from the chart that is shown on the voltage and current displays See Operation Section for complete description Figure 1 Controls and Indicators LINE Button MOD...

Page 6: ... module in position and secure with screws 5 Connect cable at rear of the display module Refer to Wiring Section Install Signal Interface Module This module is mounted close to the current sensors and voltage transformers so the cable runs are short Current and voltage information is passed to the display module over a two wire datalink 1 Measure and mark mounting location for control box mounting...

Page 7: ...ay Module Mounting Dimensions Mounting holes are clearance or tapped for 10 screws Mounting holes are clearance or tapped for 8 screws Panel Cutout 3 3 4 Diameter Module extends behind panel less than 1 2 3 1 2 3 4 4 1 4 148mm 48mm 134 5mm 4 1 4 3 1 2 94mm 67mm Display Module Control Box ...

Page 8: ...olt AC systems The transformers should be securely mounted inside the electrical box Each transformer will be connect to show line voltage phase and neutral or phase to phase for star or delta windings of the generator Refer to Wiring Section Install Optional Temperature Sensor The temperature sensor is installed as required Refer to Wiring Section Install Optional Buzzer Install the buzzer close ...

Page 9: ...09 9 Figure 5 Voltage Transformer Figure 4 Current Sensor Dimensions A 1 13 B 2 46 C 1 05 Dimensions D 1 1 2 H 1 3 8 W 2 3 8 MW 2 Current Sensor Ratio 150 5 Voltage Transformer Input 120 240 VAC Output 12 24 VAC 0 2A ...

Page 10: ...l audible buzzer can also be connected for audio warning Voltage Out Of Range Warning If the output voltage 120 240 VAC is below 80 200 VAC or above 140 270 VAC the voltage display flashes This gives the operator an indication that the generator output falls outside the safe operating level There is no audible alarm for the voltage out of range warning Temperature Sensor Optional This warning is a...

Page 11: ...Refer to the chart next to the LINE window Note When line selections 4 5 and 6 are active the AMPS window shows 3 dashes Leave the display in auto during normal operations to monitor all voltage and current levels Line Window Chart Description 1 A N Shows Voltage Phase A to Neutral 2 B N Shows Voltage Phase B to Neutral 3 C N Shows Voltage Phase C to Neutral 4 A B Shows Voltage Phase A to Phase B ...

Page 12: ...lay Module Wiring Dual Display For a dual display configuration a 4 Pin Y cable FRC P N XE XXDLY4 C1A is connected to the signal interface module 4 Pin connector Two display extension cables FRC P N XE FD7DISP2 C10A and two display modules can be connected 1 The 6 Pin connector from the display module is wired to the signal interface module 4 Pin connector The two buzzer wires are pig tailed off 2...

Page 13: ...r 2 5 Purple Voltage Transformer 3 6 Tan Voltage Transformer 3 7 Pink Current Sensor 1 8 Gray Current Sensor 1 9 Yellow Current Sensor 2 10 Brown Current Sensor 2 11 Red Current Sensor 3 12 Black Current Sensor 3 4 Pin Connector and Cable Pin Wire Color Description 1 Red 12 VDC Supply to the Display 2 Black 12 VDC Supply to the Display 3 White Datalink 4 Green Datalink Figure 7 Signal Interface Mo...

Page 14: ...24 VAC To FROG Primary AC Input 120 240 VAC From Generator Voltage Transformer Cable Refer to Figure 7 Figure 8 Voltage Transformer Wiring Voltage Transformers Black Wires Blue Wires Green Wire Blue Wire Phase A Black Wires Blue Wires Orange Wire White Wire Phase B Black Wires Blue Wires Purple Wire Tan Wire Phase C ...

Page 15: ...able Refer to Figure 7 Pink Wire Gray Wire Yellow Wire Brown Wire Red Wire Black Wire White Wire Black Wire White Wire Black Wire White Wire Black Wire Phase A Phase B Phase C Figure 9 Current Sensor Wiring Current Sensors From Generator ...

Page 16: ... Star Winding Connections A B C N 120v 1 2 0 v 1 2 0 v Star Circuit Star Winding Connections 12 Pin Deutsch Receptacle to Gray Connector Refer to Figure 7 From Generator N C B A N C B A To Load Current Sensors Voltage Transformers ...

Page 17: ...d Current Sensors Voltage Transformers Recommended Delta Circuit Reference Wiring A B C N 1 2 0 v 1 2 0 v 2 4 0 v 208v 240v Note 1 If the voltage reading needs Calibration adjust AB line 4 BC line 5 CA line 6 Ref OEM Calibration Guide Note 2 If the phase A C is split for Neutral reverse the wiring for phase B C If the phase B C is split for Neutral reverse the wiring for phase A C ...

Page 18: ...FDA700 Rev160509 18 NOTES ...

Page 19: ...FDA700 Rev160509 19 NOTES ...

Page 20: ...FDA700 Rev160509 20 ...

Reviews: