![FRC FDA700 for Delta Winding Instruction Manual Download Page 12](http://html1.mh-extra.com/html/frc/fda700-for-delta-winding/fda700-for-delta-winding_instruction-manual_2329240012.webp)
FDA700 Rev160509
12
WIRING
The following figures include the schematics, wiring diagrams, block diagrams,
and cables for the three phase generator display system.
Connectors and Cables
6 Pin Connector and Cable
Pin Wire Color Description
1
Red
+12 VDC
2
Black
–12 VDC
3
White
Datalink (+)
4
Green
Datalink (–)
5
Blue
12 VDC
6
Brown
Buzzer Ground
Figure 6. Display Module Wiring
Dual Display
For a dual display configuration a 4-Pin Y-cable (FRC P/N XE-XXDLY4-C1A)
is connected to the signal interface module 4-Pin connector. Two display extension
cables (FRC P/N XE-FD7DISP2-C10A) and two display modules can be connected.
1
—
The 6-Pin connector from
the display module is wired
to the signal interface
module 4-Pin connector.
The two buzzer wires are
pig-tailed off.
2—Power is supplied to the
display unit from the signal
interface module.
Notes
Blue —
Brown — Buzzer –
4-Pin Plug
Connected to the Signal Interface Module