QUICK INSTALLATION GUIDE (FHP)
11
Communications Wiring
•
Connect a
Com Kit (4G & Wifi)
cable to
Activate
the aGate X commissioning
functions.
•
Communications Cable Preparation
① Remove the
insulation jacket from the cable.
② Fan the wires in the order of
568B
(
white/orange, solid orange, white/green, solid
blue, white/blue, solid green, white/brown,
solid brown
). Insert the wires into the connector.
③ Crimp the connector using a
crimping tool.
•
Connect the aGate X to the network for remote access to the FHP
To ensure the reliability of remote communications, it is recommended to insert the home
network cable with an internet connection into the
Eth2
port of the EMS module, in order to
enable the remote communications function.
Wireless module
EMS module
Com Kit
(4G & Wifi
)
WARNING:
Use only the USB cable
supplied with the
equipment. The aGate X
cannot be activated if this
step is not completed.
①
②
③
WARNING:
➢
The cable from the household network may only be
connected to the Eth2 port, as Eth1 port is used for
support.
➢
The network cable needs to be made on site using
a crimping tool according to the 568B standard.
Bending of a unibody cable inside the aGate X may
prevent the inner cover from closing.
WARNING:
Before using the made cable, test
it with a wire tracker to ensure
that the cable is correct
.
When testing, the cable must be
disconnected from the device
.