6
| EN
SERVICE INSTRUCTIONS
WARNING
MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY
COMPONENT.
NOTE: This unit is permanently lubricated. Oiling is not required.
1.
Be certain the power cord is in good condition and has no nicks or cuts. The power cord on these units cannot be replaced. In case of damage the whole unit must be
replaced.
2.
Remove the intake screen (item 1) from the pump. Screen is snapped on and can be removed by pulling on it.
3.
Remove the three screws (item 2) that secure the volute to the pump housing. (DO NOT remove other screws that may be exposed.)
4.
Remove the volute (item 3) and the gasket (item 5). DO NOT remove the impeller (item 4).
5.
Lightly clean any corrosion or debris which may clog the impeller. Use a brush and penetrating oil and lightly scrape to remove encrusted material.
6.
Turn the impeller by hand to make sure it turns freely. Set the pump down so the pump and impeller are not touching anything. Plug the unit into the GFCI circuit for
10 seconds to see if the impeller turns.
•
If it is rotating and GFCI did not trip, unplug unit and install parts in reverse order in which they were removed.
•
If the impeller does not rotate, if pump is tripping circuit breakers, or if pump is not operating properly after being cleaned, return the pump to an authorized
service center. DO NOT attempt repairs yourself.
REPLACEMENT PARTS
Catalog Number
Item
Part No.
Description
PE-1
518200
PE-1H
518203
PE-1F-IF
518039
1
118901
Intake screen
1
1
1
2
902417
Screw
3
3
3
3
101375
Volute, smooth
1
-
1
3
118340
Volute, hooded
-
1
-
4
118441
Impeller
1
1
1
5
101604
Gasket
1
1
1
Note: Only the part numbers shown can be purchased for replacement.