Re-calibration of Control Head
There are times, especially after servicing, that the Inline 400 needs to be re-calibrated. This is necessary in order to re-establish a reference point for
the indication of flow. Follow these procedures for Field Flow Calibration:
1. Before powering the unit on, verify there is no water flowing in the system. This will ensure that the flow piston is in the fully seated
(zero flow) position.
2. While holding down the push button on the status display, plug the unit's power cord into the receptacle (or switch on breaker,
if hard-wired). Continue holding down the button for five seconds until both the green and red LEDs blink, indicating calibration
is complete. Release the button and the red LED should come on solid, indicating calibration was successful.
3. Open valves/taps to begin water flow and confirm unit is operating properly.
Outline Dimensions for Inline 400
Model Description
Order No.
Pump Housing Wrench
305572001
Inlet or Outlet Pressure Switch (40 psi)
305572007
Replacement Pump Housing
305572009
Replacement Control Cap w/ Display
305572010
Replacement Mounting Base
305572011
Motor Capacitor - 115 V (w/ boot)
305572012
Motor Capacitor - 230 V (w/ boot)
305572013
Power Cord - 115 V
305572014
Power Cord - 230 V
305572015
Flow Piston Kit
305572016
Pump Housing O-ring
305572017
Outdoor Protective Cap Kit
305572018
[225] 8.86
[45] 1.77
[35] 1.38
[146] 5.75
[90] 3.54
[25] 0.98
[234] 9.21
[216] 8.50
[117] 4.61
[225] 8.86
[95] 3.74
[194] 7.64
[444] 17.48
[752] 29.61
Summary of Contents for Inline400
Page 1: ...INLINE PRESSURE BOOSTING SYSTEM Owner s Manual ...
Page 21: ...21 NOTES ...
Page 22: ...22 NOTES ...
Page 23: ...23 NOTES ...
Page 25: ...SISTEMA DE PRESURIZACIÓN INLINE Manual del usuario ...
Page 45: ...21 NOTAS ...
Page 46: ...22 NOTAS ...
Page 47: ...23 NOTAS ...
Page 49: ...SYSTÈME DE SURPRESSION INLINE Manual du propriétaire ...
Page 69: ...21 REMARQUES ...
Page 70: ...22 REMARQUES ...
Page 71: ...23 REMARQUES ...