TROUBLESHOOTING GUIDE
Condition
Indicator Lights
Possible Cause
Corrective Action
Unit will not turn on - No GREEN or
RED LED illuminated on control cap
None
Circuit breaker tripped or turned off
Turn on the circuit breaker
None
Circuit breaker tripped or turned off
Consult a licensed electrician to
properly wire outlet
Unit runs briefly, won't develop
pressure, then turns off
Flashing Green (10s)
then flashing RED
Insufficient water
Check water supply and valving
Flashing Green (10s)
then flashing RED
Unit insufficiently primed
Refer to owner’s manual section on proper
priming technique
Flashing Green (10s)
then flashing RED
Dry running
Check water supply and valving
Unit won't start with water demand
Solid Green
Inlet water pressure above 40 psi
Install a pressure reducing valve on inlet to
reduce inlet pressure
Unit continuously cycles ON/OFF
(Rapid Cycle)
Flashing Green
Improper charge pressure in tank
Set the pressure in pressure tank to 2 psi
lower than cut-in pressure
Flashing Green
Check valve between tank and unit
Place check valve after pressure tank
Unit won't turn on
Solid RED
Unit is turned OFF
Press the power button on the user interface
Flashing RED
Overvoltage (input voltage higher than +10%)
Check the supply voltage and correct if possible
Flashing RED
Undervoltage (input voltage lower than -10%)
Check the supply voltage and correct if possible
Flashing RED
Overheating due to excessive water temperature Supply cold water to the pump
Flashing RED
Pump is in alarm condition
Reset pump by pressing power button
Unit runs or cycles continuously
Flashing Green
Leak/usage above 1/2 gpm in system plumbing
Repair the leaking plumbing
Flashing Green
Internal non-return valve is blocked/damaged
Place a new non-return valve before unit in
INLET plumbing
Flashing Green
Internal flow piston is stuck open
Clean the flow piston (see page 14)
NOTE:
The motor in this unit contains thermal protection that responds to motor current and heat from the motor winding and ambient
temperature. When the combination of current and heat exceeds a pre-determined point, the protector opens and interrupts the circuit.
When the winding temperature returns to a more normal level, the protector will automatically reset.
Summary of Contents for Inline400
Page 1: ...INLINE PRESSURE BOOSTING SYSTEM Owner s Manual ...
Page 21: ...21 NOTES ...
Page 22: ...22 NOTES ...
Page 23: ...23 NOTES ...
Page 25: ...SISTEMA DE PRESURIZACIÓN INLINE Manual del usuario ...
Page 45: ...21 NOTAS ...
Page 46: ...22 NOTAS ...
Page 47: ...23 NOTAS ...
Page 49: ...SYSTÈME DE SURPRESSION INLINE Manual du propriétaire ...
Page 69: ...21 REMARQUES ...
Page 70: ...22 REMARQUES ...
Page 71: ...23 REMARQUES ...