background image

G

 INTRODUCTION

This instruction sheet will provide you with information required to 
safely own and operate Little Giant PES Series pump. The pump 
you have purchased is a submersible epoxy encapsulated pump, 
with outer case constructed of durable thermoplastic. The case is 
filled with a special heat transfer epoxy.
The instruction sheet primarily covers the standard models of each 
pump series. The form is applicable to other models in the series 
not listed by catalog number in the replacement parts list section 
of the instruction sheet. If the catalog number of your pump is not 
listed in the replacement parts list section, then caution should be 
exercised when ordering replacement parts. Always give the 
catalog number of your pump when ordering replacement parts.
The Little Giant unit you have purchased is of the highest quality 
workmanship and material. It has been engineered to give you 
long and trouble-free service. The Little Giant pumps are care-
fully packaged, inspected and tested to insure safe operation 
and delivery. When you receive your pump, examine it carefully 
to determine that there are no broken or damaged parts that may 
have occurred during shipment. If damage has occurred, make 
notation and notify the firm that you purchased the pump from. 
They will assist you in replacement or repair, if required.

READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING 
TO INSTALL, OPERATE OR SERVICE THE LITTLE GIANT 
PUMP. KNOW THE PUMP APPLICATION, LIMITATIONS, AND 
POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS 
BY OBSERVING ALL SAFETY INFORMATION. FAILURE 
TO COMPLY WITH INSTRUCTIONS COULD RESULT IN 
PERSONAL  INJURY AND/OR PROPERTY DAMAGE! RETAIN 
INSTRUCTIONS FOR FUTURE REFERENCE.

SAFETY GUIDELINES

 1. Make certain that the unit is disconnected from the power 

source before attempting to service or remove any compo-
nent.

 2. Do not use to pump flammable or explosive fluids such as 

gasoline, fuel oil, kerosene, etc. Do not use in explosive atmo-
spheres. Pump should only be used with clean water. Do not 
use to pump heated liquids.

 3. Do not handle pump with wet hands or when standing on a 

wet or damp surface or in water.

 4. This pump is supplied with a grounding conductor and/or 

grounding-type attachment plug. To reduce the risk of electric 
shock, be certain that it is connected to a properly grounded 
grounding-type receptacle.

 5. In any installation where property damage and/or personal 

injury might result from an inoperative or leaking pump due to 
power outages, discharge line blockage, or any other reason, 
a backup system(s) and/or alarm should be used.

 6. Support pump and piping when assembling and when 

installed. Failure to do so may cause piping to break, pump to 
fall, motor failures, etc.

ELECTRICAL CONNECTIONS

  1.  Check the pump label for proper voltage required. Do not connect 

to voltage other than that shown.

 2. These pumps are supplied with a 3-prong electrical plug, the 

third prong is to ground the pump to prevent possible electri-
cal shock hazard. 

DO NOT REMOVE

 the third prong from the 

plug. A separate branch circuit is recommended. Do not use an 
extension cord. Do not cut plug from the cord. If the plug is cut 
or the cord is shortened, then this action will void the warranty.

  3. The National Electric Code requires that a ground fault circuit 

interrupter (GFCI) be used in the branch circuit supplying 
fountain pumps and other pond equipment. See your electrical 
supplies dealer for this device.

  4. To reduce the risk of electric shock, use only on portable self-

contained fountains no larger than five feet in any direction.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER 
ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.

OPERATION

  1. The PES model pumps must be operated in clean fresh water 

completely submerged. Do not let the pump run dry.

 2. The pumps can be placed in any position. There are suction 

cup feet provided with the pump. To install the suction cups, 
wet the ends and slide them into the slots on the bottom of the 
pump housing.

  3. The weight of the pumps must be supported adequately. 

DO 

NOT

 support the pumps by the discharge connection alone.

 4. Discharge adaptors are provided with the pump. Find your 

pump model on the chart below for available discharge sizes.

  5. The flow rate on the PES Series pump can be adjusted using 

a valve on the discharge side of the pump or if flexible tubing 
is used, a clamp can be used on the tubing.

 6. If the unit is going to be idle for a period of time, follow the 

cleaning instructions outlined in the next section. Do not let 
the unit freeze in the wintertime. This may cause cracking or 
distortion that may destroy the unit.

SERVICE INSTRUCTIONS

MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM 
THE  POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR 
REMOVE ANY COMPONENT!
  1. This unit is permanently lubricated. Oiling is not required.
  2.  To disassemble the pump for cleaning, remove the front screen 

by gently squeezing on the sides and pulling from the main 
body in the oval area. Remove the impeller. 

NOTE:

 The impel-

ler shaft is held in place by two rubber end cups (one at each 
end). Make sure these end cups are used when reassembling 
the pump after cleaning. Use a small brush or stream of water 
to clean any corrosion or debris from the impeller, shaft, and 
the impeller cavity. Reassemble the parts in reverse order.

 3. If pump is tripping circuit breakers or not operating properly 

after cleaning, return it to Little Giant or its authorized service 
center. 

DO NOT

 attempt repairs yourself.

 4. Be certain power cord is in good condition and contains no 

nicks or cuts.

  5. Do not modify, cut, saw, sand or grind any part of the pump. 

Doing so can cause harmful emissions.

1

PES-230-PW

PES-380-PW

PES-510-PW

PES-800-PW

Little Giant

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

Summary of Contents for 566713

Page 1: ...PES 700 PW 566720 0 75 57 15 3 4 725 560 400 8 25 PES 800 PW 566721 0 95 109 15 3 4 875 750 625 175 11 75 PES 1000 PW 566722 1 4 160 15 1 1150 965 775 200 11 75 PES 700 PW PES 40 PW PES 80 PW A B C PES 1000 PW 800 700 380 290 130 80 40 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 0 2 4 6 8 10 12 0 200 400 600 800 1000 1200 HEAD M HEAD FT FLOW GPH FLOW LPH IN 1000S 3YR WARRANTY Des...

Page 2: ...her than that shown 2 These pumps are supplied with a 3 prong electrical plug the third prong is to ground the pump to prevent possible electri cal shock hazard DO NOT REMOVE the third prong from the plug A separate branch circuit is recommended Do not use an extension cord Do not cut plug from the cord If the plug is cut or the cord is shortened then this action will void the warranty 3 The Natio...

Page 3: ...ompe et la tuyauterie lors de l assemblage et une fois l installation terminée Ne pas suivre cette consigne peut causer des bris de tuyauterie une chute de la pompe des défaillances du moteur etc CONNEXIONS ELECTRIQUES 1 Vérifier l étiquette de la pompe pour connaître la tension appropriée Ne pas connecter à une tension autre que celle indiquée sur l étiquette 2 Ces pompes sont fournies avec une f...

Page 4: ...s o cuando se encuentre parado sobre el suelo mojado húmedo o cubierto con agua 4 Esta bomba se suministra con un conductor de conexión a tierra y o un enchufe de tipo de conexión a tierra Para reducir el riesgo de choque eléctrico asegúrese de que esté conecta do a un receptáculo de conexión a tierra con la conexión a tierra apropiada 5 Se debe utilizar uno o varios sistemas de respaldo y o alarm...

Page 5: ...a extremo Asegúrese de que los sujetadores terminales se 4 utilicen al volver a armar la bomba después de la limpieza Utilice un cepillo pequeño o un chorro de agua para limpiar cualquier corrosión o desperdicio del impulsor eje y espacio donde va el impulsor Vuelva a armar la bomba en el orden inverso en que se realizó el desarmado 3 Si la bomba activa los cortacircuitos o no funciona debidam ent...

Page 6: ...nd Cups assy Turbine Rotor Arbre 2 Ventouses ensemble Impulsor rotor eje dos sujetadores terminales conjunto 166034 166038 166043 166054 5 Base Plate with 4 Suction Cups Plaque d appui avec 4 ventouses Placa base con 4 succionadores 166035 166039 166044 166044 6 Discharge Adapter 1 2 MNPT Adaptateur d évacuation 12 7 mm 1 2 po MNPT Adaptador de descarga MNPT de 12 7 mm 1 2 pulg N A 166006 166006 1...

Page 7: ...n therewith Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country The National Electric Code in the ...

Page 8: ... una breve explicación por escrito del problema Si no existen señas aparentes de abuso por parte del cliente la unidad será reemplazada o reparada Si se produce una disputa sobre el reemplazo de la bomba el distribuidor o vendedor debe sepa rar los artículos y retenerlos para que sean inspeccionados por un representante de Little Giant Pump Company o avisarle a la fábrica de los detalles del probl...

Page 9: ...sistance please contact 1 888 956 0000 Pour des parties ou la réparation entrez s il vous plaît en contact 1 888 572 9933 Pour l aide technique entrez s il vous plaît en contact 1 888 956 0000 Para partes o la reparación por favor póngase en contacto 1 888 572 9933 Para la ayuda técnica por favor póngase en contacto 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com ...

Reviews: